Progress of development of Thomson scattering diagnostic system on COMPASS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F10%3A00349453" target="_blank" >RIV/61389021:_____/10:00349453 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Progress of development of Thomson scattering diagnostic system on COMPASS
Popis výsledku v původním jazyce
Thomson scattering (TS) is widely applied in the field of high-temperature plasma diagnostics for highly localized measurements of the electron temperature and density in the plasma. Two multipoint TS diagnostics with high spatial resolution, one focusedon the core plasma and one on the edge plasma, are being developed on the COMPASS tokamak. TS on COMPASS is based on a set of two Nd:YAG lasers (1064 nm, 30 Hz, and 1.5 J each), two objectives collecting the light from both the core and edge plasma regions and number of polychromators equipped by Avalanche photodiodes and spectral filters. Both conceptual and detailed designs of most parts of the diagnostic as well as procurement phase were finished in 2009. In this paper, progress in development of TS, focusing on assembling and testing of particular items, is summarized. The detailed description of port plug structure and unique design of collection objective are given for both the core and the edge TS diagnostics.
Název v anglickém jazyce
Progress of development of Thomson scattering diagnostic system on COMPASS
Popis výsledku anglicky
Thomson scattering (TS) is widely applied in the field of high-temperature plasma diagnostics for highly localized measurements of the electron temperature and density in the plasma. Two multipoint TS diagnostics with high spatial resolution, one focusedon the core plasma and one on the edge plasma, are being developed on the COMPASS tokamak. TS on COMPASS is based on a set of two Nd:YAG lasers (1064 nm, 30 Hz, and 1.5 J each), two objectives collecting the light from both the core and edge plasma regions and number of polychromators equipped by Avalanche photodiodes and spectral filters. Both conceptual and detailed designs of most parts of the diagnostic as well as procurement phase were finished in 2009. In this paper, progress in development of TS, focusing on assembling and testing of particular items, is summarized. The detailed description of port plug structure and unique design of collection objective are given for both the core and the edge TS diagnostics.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
81
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000283754000069
EID výsledku v databázi Scopus
—