Plasma agents in water and surface decontamination(NATO ,Jasná 2011)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F11%3A00369923" target="_blank" >RIV/61389021:_____/11:00369923 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Plasma agents in water and surface decontamination(NATO ,Jasná 2011)
Popis výsledku v původním jazyce
Předneseno:NATO Advanced Research Workshop on "Plasma for bio-decontamination, medicine and food security",Jasná,15-18.03.2011,str.45-46; Bio-decontamination of water and surfaces contaminated by bacteria (Salmonella typhimurium, Bacillus cereus, Escherichia coli) was investigated in two types of positive DC discharges in atmospheric pressure air, in needle-to-plane geometry: the streamer corona and the transient spark with short high current pulses of limited energy. Both generate cold non-equilibriumplasma. Electro-spraying of the treated water through the needle electrode resulted in fast bio-decontamination. Experiments providing separation of various biocidal plasma agents, the emission spectra, oxidation stress measurements in the cell membranes, and chemical changes induced in the treated water helped better understanding of the plasma agents responsible for microbial inactivation. Radicals and reactive oxygen species seem to be dominant biocidal agents, although understandin
Název v anglickém jazyce
Plasma agents in water and surface decontamination(NATO ,Jasná 2011)
Popis výsledku anglicky
Předneseno:NATO Advanced Research Workshop on "Plasma for bio-decontamination, medicine and food security",Jasná,15-18.03.2011,str.45-46; Bio-decontamination of water and surfaces contaminated by bacteria (Salmonella typhimurium, Bacillus cereus, Escherichia coli) was investigated in two types of positive DC discharges in atmospheric pressure air, in needle-to-plane geometry: the streamer corona and the transient spark with short high current pulses of limited energy. Both generate cold non-equilibriumplasma. Electro-spraying of the treated water through the needle electrode resulted in fast bio-decontamination. Experiments providing separation of various biocidal plasma agents, the emission spectra, oxidation stress measurements in the cell membranes, and chemical changes induced in the treated water helped better understanding of the plasma agents responsible for microbial inactivation. Radicals and reactive oxygen species seem to be dominant biocidal agents, although understandin
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/MEB0810116" target="_blank" >MEB0810116: Biologická a chemická dekontaminace vody elektrickými výboji</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů