A kinetic model of retarding field analyser measurements in strongly magnetized, flowing, collisional plasmas
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F13%3A00421661" target="_blank" >RIV/61389021:_____/13:00421661 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/0741-3335/55/4/045012" target="_blank" >http://dx.doi.org/10.1088/0741-3335/55/4/045012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0741-3335/55/4/045012" target="_blank" >10.1088/0741-3335/55/4/045012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A kinetic model of retarding field analyser measurements in strongly magnetized, flowing, collisional plasmas
Popis výsledku v původním jazyce
Interpretation of retarding field analyser (RFA) measurements in flowing tokamak scrape- off layer plasmas requires a model of the perturbation introduced by the wake, or presheath, of the instrument. We extend a collisionless kinetic Mach probe theory to include a simple model of ion-ion collisions. Collisions lead to significant modifications in the downstream presheath. Depending on the ion-to-electron temperature ratio, flow speed and collisionality, the measurement obtained by averaging the apparent temperatures on each side of a bi-directional RFA is predicted to overestimate the unperturbed ion temperature, but with errors not exceeding 50% most of the time. The error increases with Mach number, and decreases with the ion-to-electron temperatureratio.
Název v anglickém jazyce
A kinetic model of retarding field analyser measurements in strongly magnetized, flowing, collisional plasmas
Popis výsledku anglicky
Interpretation of retarding field analyser (RFA) measurements in flowing tokamak scrape- off layer plasmas requires a model of the perturbation introduced by the wake, or presheath, of the instrument. We extend a collisionless kinetic Mach probe theory to include a simple model of ion-ion collisions. Collisions lead to significant modifications in the downstream presheath. Depending on the ion-to-electron temperature ratio, flow speed and collisionality, the measurement obtained by averaging the apparent temperatures on each side of a bi-directional RFA is predicted to overestimate the unperturbed ion temperature, but with errors not exceeding 50% most of the time. The error increases with Mach number, and decreases with the ion-to-electron temperatureratio.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7G10072" target="_blank" >7G10072: Joint carrying out by the Contracting Parties of activities within the thematic area "fusion energy research" of the Seventh Community (Euratom) Framework Program</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Plasma Physics and Controlled Fusion
ISSN
0741-3335
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
045012-045012
Kód UT WoS článku
000317739800012