Preliminary Measurements of Neutrons From The D-D Reaction in The Compass Tokamak
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F14%3A00487617" target="_blank" >RIV/61389021:_____/14:00487617 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4894034" target="_blank" >http://dx.doi.org/10.1063/1.4894034</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4894034" target="_blank" >10.1063/1.4894034</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Preliminary Measurements of Neutrons From The D-D Reaction in The Compass Tokamak
Popis výsledku v původním jazyce
Recent results of measured fast neutrons created in the D-D reaction on the COMPASS tokamak during ohmic discharges are presented in this paper. Two different type detectors were used during experiment. He-3 detectors and bubble detectors as a support. The measurements are an introduction for neutron diagnostic on tokamak COMPASS and monitoring neutrons during discharges with Neutral Beam Injection (NBI). The He-3 counters and bubble detectors were located in two positions near tokamak vacuum chamber at a distance less than 40 cm to the centre of plasma. The neutrons flux was observed in ohmic discharges. However, analysis of our results does not indicate any clear source of neutrons production during ohmic discharges.
Název v anglickém jazyce
Preliminary Measurements of Neutrons From The D-D Reaction in The Compass Tokamak
Popis výsledku anglicky
Recent results of measured fast neutrons created in the D-D reaction on the COMPASS tokamak during ohmic discharges are presented in this paper. Two different type detectors were used during experiment. He-3 detectors and bubble detectors as a support. The measurements are an introduction for neutron diagnostic on tokamak COMPASS and monitoring neutrons during discharges with Neutral Beam Injection (NBI). The He-3 counters and bubble detectors were located in two positions near tokamak vacuum chamber at a distance less than 40 cm to the centre of plasma. The neutrons flux was observed in ohmic discharges. However, analysis of our results does not indicate any clear source of neutrons production during ohmic discharges.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2011021" target="_blank" >LM2011021: COMPASS-RI - příspěvek na provoz a základní personální zajištění tokamaku COMPASS - velké výzkumné infrastruktury celoevropského významu</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings:FUSION REACTOR DIAGNOSTICS
ISBN
978-0-7354-1248-4
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
109-112
Název nakladatele
American Institute of Physics
Místo vydání
MELVILLE
Místo konání akce
Villa Monastero,Varenna
Datum konání akce
9. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000343712300019