Fast measurements of the electron temperature in divertor region of the COMPASS tokamak using ball-pen probe
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F15%3A00453933" target="_blank" >RIV/61389021:_____/15:00453933 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fast measurements of the electron temperature in divertor region of the COMPASS tokamak using ball-pen probe
Popis výsledku v původním jazyce
The electron temperature in divertor regions of present day devices is typically measured by swept Langmuir probes or triple probe technique. However, the measurement of its evolution during ELM filaments requires high temporal resolution, which has notbeen achieved by these techniques yet. Alternative option how to determine the electron temperature with high time resolution is to use direct measurements of the plasma and floating potentials. The electron temperature is consequently determined from the difference of both potentials normalized by the proper coefficient for specific gas and magnetic field. The floating potential is routinely measured by Langmuir probe and the plasma potential can be directly measured by ball-pen probe (BPP). Recently,a new array of BPPs and dome-shaped Langmuir probes was installed also in a divertor target of the COMPASS tokamak.
Název v anglickém jazyce
Fast measurements of the electron temperature in divertor region of the COMPASS tokamak using ball-pen probe
Popis výsledku anglicky
The electron temperature in divertor regions of present day devices is typically measured by swept Langmuir probes or triple probe technique. However, the measurement of its evolution during ELM filaments requires high temporal resolution, which has notbeen achieved by these techniques yet. Alternative option how to determine the electron temperature with high time resolution is to use direct measurements of the plasma and floating potentials. The electron temperature is consequently determined from the difference of both potentials normalized by the proper coefficient for specific gas and magnetic field. The floating potential is routinely measured by Langmuir probe and the plasma potential can be directly measured by ball-pen probe (BPP). Recently,a new array of BPPs and dome-shaped Langmuir probes was installed also in a divertor target of the COMPASS tokamak.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPS 2015:42nd European Physical Society Conference on Plasma Physics
ISBN
2-914771-98-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
"P4.101"-"P4.101"
Název nakladatele
European Physical Society
Místo vydání
Mulhouse
Místo konání akce
Lisabon
Datum konání akce
22. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—