First results from the neutral particle analyzer on the COMPASS tokamak
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F15%3A00474056" target="_blank" >RIV/61389021:_____/15:00474056 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
First results from the neutral particle analyzer on the COMPASS tokamak
Popis výsledku v původním jazyce
The Neutral Particle Analyzer (NPA) for the COMPASS tokamak was recently upgraded and absolutelyncalibrated in the Ioffe Institute, St. Petersburg. NPA allows simultaneous measurements of thenenergy spectra of fast hydrogen and deuterium atoms and determination of the ion temperature. Energynspectra of the neutral fluxes are measured by NPA in Ohmic as well as in the NBI heated plasmas. Thenmeasured ion temperature in L-mode plasmas varies in the range of 300-500 eV. After the L-H transition,nthe ion temperature increases by ΔTi ≈ 250 eV. A relatively high temporal resolution of the NPA datanacquisition system allows study of fast transient phenomena, such as the Edge Localized Mode and sawtoothnoscillation.nComparative measurement of Ti in the plasma core given by NPA and at the plasma edge usingnRetarding Field Analyzer is also reported.
Název v anglickém jazyce
First results from the neutral particle analyzer on the COMPASS tokamak
Popis výsledku anglicky
The Neutral Particle Analyzer (NPA) for the COMPASS tokamak was recently upgraded and absolutelyncalibrated in the Ioffe Institute, St. Petersburg. NPA allows simultaneous measurements of thenenergy spectra of fast hydrogen and deuterium atoms and determination of the ion temperature. Energynspectra of the neutral fluxes are measured by NPA in Ohmic as well as in the NBI heated plasmas. Thenmeasured ion temperature in L-mode plasmas varies in the range of 300-500 eV. After the L-H transition,nthe ion temperature increases by ΔTi ≈ 250 eV. A relatively high temporal resolution of the NPA datanacquisition system allows study of fast transient phenomena, such as the Edge Localized Mode and sawtoothnoscillation.nComparative measurement of Ti in the plasma core given by NPA and at the plasma edge usingnRetarding Field Analyzer is also reported.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science: 1st EPS Conference on Plasma Diagnostics, ECPD 2015
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
Proceedings of Science (PoS)
Místo vydání
Frascati
Místo konání akce
Frascati
Datum konání akce
14. 4. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—