Measurements of SOL currents by the floating divertor tile in the COMPASS tokamak (IWSSPP 2018, Kiten)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F18%3A00491929" target="_blank" >RIV/61389021:_____/18:00491929 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurements of SOL currents by the floating divertor tile in the COMPASS tokamak (IWSSPP 2018, Kiten)
Popis výsledku v původním jazyce
Předneseno na: IWSSPP 2018 - 8th International workshop and summer school on Plasma Physics,nThe divertor of the COMPASS tokamak was recently equipped with a special toroidal section dubbed floating tile, which contains a radial array of 5 insulated segments. Two segments are located at the typical radial positions of strike points, two are covering the far scrape-off layer (SOL) on each target and the middle segment is located in the private flux region. Each tile is conductively connected to an electrical feed-through, allowing for an external control of the tile connections. Dedicated electronics allows to switch each segment between a grounded and floating state during a discharge, according to a request delivered by a triggering signal. When a segment is grounded, a shunt current is measured, while in the floating state the floating potential is acquired.n
Název v anglickém jazyce
Measurements of SOL currents by the floating divertor tile in the COMPASS tokamak (IWSSPP 2018, Kiten)
Popis výsledku anglicky
Předneseno na: IWSSPP 2018 - 8th International workshop and summer school on Plasma Physics,nThe divertor of the COMPASS tokamak was recently equipped with a special toroidal section dubbed floating tile, which contains a radial array of 5 insulated segments. Two segments are located at the typical radial positions of strike points, two are covering the far scrape-off layer (SOL) on each target and the middle segment is located in the private flux region. Each tile is conductively connected to an electrical feed-through, allowing for an external control of the tile connections. Dedicated electronics allows to switch each segment between a grounded and floating state during a discharge, according to a request delivered by a triggering signal. When a segment is grounded, a shunt current is measured, while in the floating state the floating potential is acquired.n
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-14228S" target="_blank" >GA16-14228S: Redukce lokalizovaných tepelných toků v divertoru tokamaku COMPASS za pomocí aktivních technik</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů