Aiming at understanding thermo-mechanical loads in the first wall of DEMO: Stress–strain evolution in a Eurofer-tungsten test component featuring a functionally graded interlayer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F18%3A00492145" target="_blank" >RIV/61389021:_____/18:00492145 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0920379618305660?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0920379618305660?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.fusengdes.2018.07.011" target="_blank" >10.1016/j.fusengdes.2018.07.011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Aiming at understanding thermo-mechanical loads in the first wall of DEMO: Stress–strain evolution in a Eurofer-tungsten test component featuring a functionally graded interlayer
Popis výsledku v původním jazyce
For the future fusion demonstration power plant, DEMO, several blanket designs are currently under consideration.nDespite geometric and operational differences, all designs suggest a first wall (FW), in which tungsten (W) armour is joined to a structure made of Reduced Activation Ferritic Martensitic (RAFM) steel. In thermomechanical analyses of breeding blankets, this joint has received limited attention. In order to provide a basis for better understanding of thermally induced stresses and strains in the FW, the thermo-mechanical behaviour of a water-cooled test component is explored in the current contribution. The model aims at providing a simple geometry that allows straightforward comparison of numerical and experimental results, while trying to keep boundary conditions as realistic as possible. A test component with direct RAFM steel-W joint, and a test component with a stress-redistributing, functionally graded RAFM steel/W interlayer in the joint is considered in the current contribution. The analyses take production- and operation-related loads into account. Following a detailed analysis of the evolution of stress components and strain in the model, a parameter study with respect to geometric specifications and loads is presented.nThe analyses show that, even in a small test component, a direct RAFM steel-W joint causes enormous plastic deformation. The implementation of a functionally graded interlayer reduces stresses and strains significantly, but vertical normal stresses at the joint's circumference remain considerable. With the component geometry considered here, the graded interlayer should be at least 1mm thick and contain 4 sublayers to appropriately redistribute stresses. Beyond a component width of 14 mm, stresses increase strongly, which may pose a risk to the applicability of large-scale FW components, too.
Název v anglickém jazyce
Aiming at understanding thermo-mechanical loads in the first wall of DEMO: Stress–strain evolution in a Eurofer-tungsten test component featuring a functionally graded interlayer
Popis výsledku anglicky
For the future fusion demonstration power plant, DEMO, several blanket designs are currently under consideration.nDespite geometric and operational differences, all designs suggest a first wall (FW), in which tungsten (W) armour is joined to a structure made of Reduced Activation Ferritic Martensitic (RAFM) steel. In thermomechanical analyses of breeding blankets, this joint has received limited attention. In order to provide a basis for better understanding of thermally induced stresses and strains in the FW, the thermo-mechanical behaviour of a water-cooled test component is explored in the current contribution. The model aims at providing a simple geometry that allows straightforward comparison of numerical and experimental results, while trying to keep boundary conditions as realistic as possible. A test component with direct RAFM steel-W joint, and a test component with a stress-redistributing, functionally graded RAFM steel/W interlayer in the joint is considered in the current contribution. The analyses take production- and operation-related loads into account. Following a detailed analysis of the evolution of stress components and strain in the model, a parameter study with respect to geometric specifications and loads is presented.nThe analyses show that, even in a small test component, a direct RAFM steel-W joint causes enormous plastic deformation. The implementation of a functionally graded interlayer reduces stresses and strains significantly, but vertical normal stresses at the joint's circumference remain considerable. With the component geometry considered here, the graded interlayer should be at least 1mm thick and contain 4 sublayers to appropriately redistribute stresses. Beyond a component width of 14 mm, stresses increase strongly, which may pose a risk to the applicability of large-scale FW components, too.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fusion Engineering and Design
ISSN
09203796
e-ISSN
—
Svazek periodika
135
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
141-153
Kód UT WoS článku
000447082300019
EID výsledku v databázi Scopus