Runaway electron diagnostics for the COMPASS tokamak using EC emission
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F18%3A00531279" target="_blank" >RIV/61389021:_____/18:00531279 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.epj-conferences.org/articles/epjconf/pdf/2019/08/epjconf_ec2018_03006.pdf" target="_blank" >https://www.epj-conferences.org/articles/epjconf/pdf/2019/08/epjconf_ec2018_03006.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201920303006" target="_blank" >10.1051/epjconf/201920303006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Runaway electron diagnostics for the COMPASS tokamak using EC emission
Popis výsledku v původním jazyce
An electron cyclotron emission (ECE) diagnostic of suprathermal electrons was utilised for runaway electron (RE) experiments purposes in the COMPASS tokamak. Our vertical ECE (V-ECE) system consists of a 16-channel heterodyne radiometer and an E-band horn antenna with a 76.5-88 GHz frequency range front-end. Simulations used for the design of the diagnostic showed a possibility of detecting the emission of low-energy (50-140 keV) runaway electrons. We realized measurements with both extraordinary (X-) and ordinary (O-) mode linear polarizations. The amplitudes of the X-mode and O-mode signals are similar, which can be explained by depolarised reflected radiation. V-ECE measurements in low-density flattop discharges and in discharges with massive gas injections of high-Z elements show correlations with other RE diagnostics. Our results are in the agreement with the principles of the primary runaway generation mechanisms.
Název v anglickém jazyce
Runaway electron diagnostics for the COMPASS tokamak using EC emission
Popis výsledku anglicky
An electron cyclotron emission (ECE) diagnostic of suprathermal electrons was utilised for runaway electron (RE) experiments purposes in the COMPASS tokamak. Our vertical ECE (V-ECE) system consists of a 16-channel heterodyne radiometer and an E-band horn antenna with a 76.5-88 GHz frequency range front-end. Simulations used for the design of the diagnostic showed a possibility of detecting the emission of low-energy (50-140 keV) runaway electrons. We realized measurements with both extraordinary (X-) and ordinary (O-) mode linear polarizations. The amplitudes of the X-mode and O-mode signals are similar, which can be explained by depolarised reflected radiation. V-ECE measurements in low-density flattop discharges and in discharges with massive gas injections of high-Z elements show correlations with other RE diagnostics. Our results are in the agreement with the principles of the primary runaway generation mechanisms.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
45th EPS Conference on Plasma Physics, EPS 2018
ISBN
979-10-96389-08-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
"Roč. 45"
Název nakladatele
European Physical Society
Místo vydání
Mulhouse
Místo konání akce
Praha
Datum konání akce
2. 7. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—