Overview of power exhaust experiments in the COMPASS divertor with liquid metals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F20%3A00533928" target="_blank" >RIV/61389021:_____/20:00533928 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/20:00373524
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2352179120300776?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2352179120300776?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nme.2020.100801" target="_blank" >10.1016/j.nme.2020.100801</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Overview of power exhaust experiments in the COMPASS divertor with liquid metals
Popis výsledku v původním jazyce
Power handling experiments with a special liquid metal divertor module based on the capillary porous system technology were performed in the tokamak COMPASS. The performance of two metals (Li and LiSn alloy) were tested for the first time in a divertor under ELMy H-mode conditions. No damage of the capillary mesh and a good exhaust capability were observed for both metals in two separate experiments with up to 12 MW/m2 of deposited perpendicular, inter-ELM steady-state heat flux and with ELMs of relative energy ~3% and a local peak energy fluence at the module ~15 kJ.m−2. No droplets were directly ejected from the mesh top surface and for the LiSn experiment, no contamination of the core and SOL plasmas by Sn was observed. The elemental depth profile analysis of 14 stainless-steel samples located around the vacuum vessel for each experiment provides information about the migration of evaporated/redeposited liquid elements.
Název v anglickém jazyce
Overview of power exhaust experiments in the COMPASS divertor with liquid metals
Popis výsledku anglicky
Power handling experiments with a special liquid metal divertor module based on the capillary porous system technology were performed in the tokamak COMPASS. The performance of two metals (Li and LiSn alloy) were tested for the first time in a divertor under ELMy H-mode conditions. No damage of the capillary mesh and a good exhaust capability were observed for both metals in two separate experiments with up to 12 MW/m2 of deposited perpendicular, inter-ELM steady-state heat flux and with ELMs of relative energy ~3% and a local peak energy fluence at the module ~15 kJ.m−2. No droplets were directly ejected from the mesh top surface and for the LiSn experiment, no contamination of the core and SOL plasmas by Sn was observed. The elemental depth profile analysis of 14 stainless-steel samples located around the vacuum vessel for each experiment provides information about the migration of evaporated/redeposited liquid elements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Materials and Energy
ISSN
2352-1791
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
100801
Kód UT WoS článku
000600734700018
EID výsledku v databázi Scopus
2-s2.0-85094122660