Disruption mitigation efficiency and scaling with thermal energy fraction on ASDEX Upgrade
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F20%3A00538147" target="_blank" >RIV/61389021:_____/20:00538147 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1741-4326/abb425" target="_blank" >https://iopscience.iop.org/article/10.1088/1741-4326/abb425</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1741-4326/abb425" target="_blank" >10.1088/1741-4326/abb425</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Disruption mitigation efficiency and scaling with thermal energy fraction on ASDEX Upgrade
Popis výsledku v původním jazyce
Disruption mitigation remains a critical and unresolved issue for ITER. Measurement uncertainties preventing quantification of a system's efficacy remains a significant hurdle in producing and validating a viable disruption mitigation system. This study addresses this issue through the creation of a dataset on the ASDEX Upgrade tokamak targeted at developing analysis techniques to quantify mitigation that are applicable irrespective of the disruption mitigation system being studied. These experiments used a range of thermal energy fractions to address concerns for ITER from JET massive gas injection (MGI) experiments showing a decrease in efficacy with increasing thermal energy fraction. The dataset produced in this study used MGI valves in two toroidal locations. The high resolution foil bolometers and AXUV diode arrays were used to infer radiation emission profiles at varying toroidal distances from the injection location. The fueling efficiency of the two systems was found to be comparable and toroidal asymmetries over the entire disruption were found to be negligible. The AXUV diodes were cross-calibrated with the foil bolometers and used to estimate the thermal energy radiated and magnetic energy coupled to the vessel structure and coils. It was estimated that 75-95% of the thermal energy was radiated and an almost constant 60% of the total magnetic energy was coupled. Radiated energy fractions of 0.8-1.0 were calculated and no decrease as a function of thermal energy fraction was found. A ? 20% variation in the coupled magnetic energy was explored and it did not alter this trend.
Název v anglickém jazyce
Disruption mitigation efficiency and scaling with thermal energy fraction on ASDEX Upgrade
Popis výsledku anglicky
Disruption mitigation remains a critical and unresolved issue for ITER. Measurement uncertainties preventing quantification of a system's efficacy remains a significant hurdle in producing and validating a viable disruption mitigation system. This study addresses this issue through the creation of a dataset on the ASDEX Upgrade tokamak targeted at developing analysis techniques to quantify mitigation that are applicable irrespective of the disruption mitigation system being studied. These experiments used a range of thermal energy fractions to address concerns for ITER from JET massive gas injection (MGI) experiments showing a decrease in efficacy with increasing thermal energy fraction. The dataset produced in this study used MGI valves in two toroidal locations. The high resolution foil bolometers and AXUV diode arrays were used to infer radiation emission profiles at varying toroidal distances from the injection location. The fueling efficiency of the two systems was found to be comparable and toroidal asymmetries over the entire disruption were found to be negligible. The AXUV diodes were cross-calibrated with the foil bolometers and used to estimate the thermal energy radiated and magnetic energy coupled to the vessel structure and coils. It was estimated that 75-95% of the thermal energy was radiated and an almost constant 60% of the total magnetic energy was coupled. Radiated energy fractions of 0.8-1.0 were calculated and no decrease as a function of thermal energy fraction was found. A ? 20% variation in the coupled magnetic energy was explored and it did not alter this trend.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Fusion
ISSN
0029-5515
e-ISSN
—
Svazek periodika
60
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
15
Strana od-do
126029
Kód UT WoS článku
000577197500001
EID výsledku v databázi Scopus
2-s2.0-85094318188