Noise effect on 2D photoluminescence decay analysis using the RATS method in a single-pixel camera configuration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F22%3A00569065" target="_blank" >RIV/61389021:_____/22:00569065 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24220/22:00010200
Výsledek na webu
<a href="https://opg.optica.org/oe/fulltext.cfm?uri=oe-30-8-12654&id=470959" target="_blank" >https://opg.optica.org/oe/fulltext.cfm?uri=oe-30-8-12654&id=470959</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/OE.450613" target="_blank" >10.1364/OE.450613</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noise effect on 2D photoluminescence decay analysis using the RATS method in a single-pixel camera configuration
Popis výsledku v původním jazyce
Using a random temporal signal for sample excitation (RATS method) is a new, capable approach to measuring photoluminescence (PL) dynamics. The method can be used in single-point measurement (0D), but also it can be converted to PL decay imaging (2D) using a single-pixel camera configuration. In both cases, the reconstruction of the PL decay and PL snapshot is affected by ubiquitous noise. This article provides a detailed analysis of the noise effect on the RATS method and possible strategies for its suppression. We carried out an extensive set of simulations focusing on the effect of noise introduced through the random excitation signal and the corresponding PL waveform. We show that the PL signal noise level is critical for the method. Furthermore, we analyze the role of acquisition time, where we demonstrate the need for a non-periodic excitation signal. We show that it is beneficial to increase the acquisition time and that increasing the number of measurements in the single-pixel camera configuration has a minimal effect above a certain threshold. Finally, we study the effect of a regularization parameter used in the deconvolution step, and we observe that there is an optimum value set by the noise present in the PL dataset. Our results provide a guideline for optimization of the RATS measurement, but we also study effects generally occurring in PL decay measurements methods relying on the deconvolution step.
Název v anglickém jazyce
Noise effect on 2D photoluminescence decay analysis using the RATS method in a single-pixel camera configuration
Popis výsledku anglicky
Using a random temporal signal for sample excitation (RATS method) is a new, capable approach to measuring photoluminescence (PL) dynamics. The method can be used in single-point measurement (0D), but also it can be converted to PL decay imaging (2D) using a single-pixel camera configuration. In both cases, the reconstruction of the PL decay and PL snapshot is affected by ubiquitous noise. This article provides a detailed analysis of the noise effect on the RATS method and possible strategies for its suppression. We carried out an extensive set of simulations focusing on the effect of noise introduced through the random excitation signal and the corresponding PL waveform. We show that the PL signal noise level is critical for the method. Furthermore, we analyze the role of acquisition time, where we demonstrate the need for a non-periodic excitation signal. We show that it is beneficial to increase the acquisition time and that increasing the number of measurements in the single-pixel camera configuration has a minimal effect above a certain threshold. Finally, we study the effect of a regularization parameter used in the deconvolution step, and we observe that there is an optimum value set by the noise present in the PL dataset. Our results provide a guideline for optimization of the RATS measurement, but we also study effects generally occurring in PL decay measurements methods relying on the deconvolution step.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_026%2F0008390" target="_blank" >EF16_026/0008390: Partnerství pro excelenci v superpřesné optice</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optics Express
ISSN
1094-4087
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
12654-12669
Kód UT WoS článku
000781729800039
EID výsledku v databázi Scopus
2-s2.0-85128175064