Embedded-probes diagnostics for the COMPASS upgrade tokamak: a concept
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F22%3A00570021" target="_blank" >RIV/61389021:_____/22:00570021 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1748-0221/17/11/P11018" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/17/11/P11018</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/17/11/P11018" target="_blank" >10.1088/1748-0221/17/11/P11018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Embedded-probes diagnostics for the COMPASS upgrade tokamak: a concept
Popis výsledku v původním jazyce
This article introduces a concept based on flush-mounted probes embedded in the limiters of the COMPASS-Upgrade tokamak. Main issues related to flush probe geometry are taken into account and discussed. Calculations of heat fluxes and the incident angle of the field lines on the different limiters using the PFCflux code are performed to support in probe arrangement optimization. Model current-voltage characteristics for a flush probe are simulated using the SPICE2 code and their dependence on the angle of incidence is studied. The results are used to predict the current to be collected by the flush probes for different magnetic fields and to examine the reliability of the proposed diagnostics. A discussion is included on the capability of the electronic system considered for the measurements.
Název v anglickém jazyce
Embedded-probes diagnostics for the COMPASS upgrade tokamak: a concept
Popis výsledku anglicky
This article introduces a concept based on flush-mounted probes embedded in the limiters of the COMPASS-Upgrade tokamak. Main issues related to flush probe geometry are taken into account and discussed. Calculations of heat fluxes and the incident angle of the field lines on the different limiters using the PFCflux code are performed to support in probe arrangement optimization. Model current-voltage characteristics for a flush probe are simulated using the SPICE2 code and their dependence on the angle of incidence is studied. The results are used to predict the current to be collected by the flush probes for different magnetic fields and to examine the reliability of the proposed diagnostics. A discussion is included on the capability of the electronic system considered for the measurements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
17
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
15
Strana od-do
P11018
Kód UT WoS článku
000924954800008
EID výsledku v databázi Scopus
2-s2.0-85142420977