Label-free impedimetric detection of isopentenyladenine towards noninvasive monitoring of root-microbe interactions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389030%3A_____%2F26%3A00645864" target="_blank" >RIV/61389030:_____/26:00645864 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/86652079:_____/26:00645864
Výsledek na webu
<a href="https://doi.org/10.1016/j.jelechem.2025.119682" target="_blank" >https://doi.org/10.1016/j.jelechem.2025.119682</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jelechem.2025.119682" target="_blank" >10.1016/j.jelechem.2025.119682</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Label-free impedimetric detection of isopentenyladenine towards noninvasive monitoring of root-microbe interactions
Popis výsledku v původním jazyce
Quantifying plant hormones (phytohormones) is essential for understanding plant growth and development. Among the phytohormones, cytokinins are crucial for plant growth, and have also emerged as interkingdom signaling molecules between roots and root-associated microbes. However, existing methods do not allow for non-invasive, in-situ hormone level determination in these interactions. Here we present a label-free electrochemical impedance spectroscopy (EIS) immunosensor to detect the cytokinin molecule, isopentenyladenine (iP) by immobilizing a monoclonal antibody on a self-assembled monolayer (SAM)-modified screen-printed gold electrode (SPAuE). For small molecule measurements using such antibody-based sensors, signal drift in EIS measurements is very common leading to false positive or false negative signals. To address this issue of signal drift, we incubated the antibody-modified electrodes in nitrogen-purged, deaerated phosphate-buffered saline (N-PBS), which resulted in more reproducible and accurate measurements. After incubating the immunosensor with iP in N-PBS, it had a linear response to iP in the concentration range 10-1000 nM with minimal interference towards common small molecules co-existing in plant samples. Finally, the immunosensor was incubated with spiked concentrations of iP in plant root exudate where a linear response to iP was found in the concentration range 100-1000 nM. The developed immunosensor has the potential to quantify other cytokinin molecules with minor modifications.
Název v anglickém jazyce
Label-free impedimetric detection of isopentenyladenine towards noninvasive monitoring of root-microbe interactions
Popis výsledku anglicky
Quantifying plant hormones (phytohormones) is essential for understanding plant growth and development. Among the phytohormones, cytokinins are crucial for plant growth, and have also emerged as interkingdom signaling molecules between roots and root-associated microbes. However, existing methods do not allow for non-invasive, in-situ hormone level determination in these interactions. Here we present a label-free electrochemical impedance spectroscopy (EIS) immunosensor to detect the cytokinin molecule, isopentenyladenine (iP) by immobilizing a monoclonal antibody on a self-assembled monolayer (SAM)-modified screen-printed gold electrode (SPAuE). For small molecule measurements using such antibody-based sensors, signal drift in EIS measurements is very common leading to false positive or false negative signals. To address this issue of signal drift, we incubated the antibody-modified electrodes in nitrogen-purged, deaerated phosphate-buffered saline (N-PBS), which resulted in more reproducible and accurate measurements. After incubating the immunosensor with iP in N-PBS, it had a linear response to iP in the concentration range 10-1000 nM with minimal interference towards common small molecules co-existing in plant samples. Finally, the immunosensor was incubated with spiked concentrations of iP in plant root exudate where a linear response to iP was found in the concentration range 100-1000 nM. The developed immunosensor has the potential to quantify other cytokinin molecules with minor modifications.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2026
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electroanalytical Chemistry
ISSN
1572-6657
e-ISSN
1873-2569
Svazek periodika
1001
Číslo periodika v rámci svazku
JAN 15
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
119682
Kód UT WoS článku
001635591900001
EID výsledku v databázi Scopus
2-s2.0-105029936707