Elipse, the first procedureless gastric balloon for weight loss: a prospective, observational, open-label, multicenter study.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F17%3AA1801MJL" target="_blank" >RIV/61988987:17110/17:A1801MJL - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00843989:_____/17:E0106040
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pubmed/26253980" target="_blank" >https://www.ncbi.nlm.nih.gov/pubmed/26253980</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1055/s-0042-119296" target="_blank" >10.1055/s-0042-119296</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Elipse, the first procedureless gastric balloon for weight loss: a prospective, observational, open-label, multicenter study.
Popis výsledku v původním jazyce
Background and study aims Conventional gastric balloons for weight loss require endoscopy for placement and removal. The Elipse device is swallowed, resides in the stomach for 4 months, and is then expelled. The objectives of this study were to assess the safety of Elipse and to measure its effects on weight loss, metabolic parameters, and quality of life. Methods Each participant swallowed one Elipse device, which was filled with 550mL of filling fluid through a thin delivery catheter that was then removed. Weight was measured every 2 weeks, and metabolic parameters and quality of life were assessed at baseline and at trial exit. Results 34 patients, with a mean body mass index of 34.8 kg/m(2), were enrolled. All 34 patients successfully swallowed the Elipse device. All adverse events were either self-limiting or resolved with medication. All balloons were safely excreted. At 4 months, the mean percent total body weight loss was 10%. Mean waist circumference was reduced by 8.4cm. Improvements were also seen in hemoglobin A1c, triglycerides, low density lipoprotein, and blood pressure. At trial exit, quality of life measures had improved across all domains. Conclusion These results demonstrate clinically significant weight loss with the Elipse, the first procedureless gastric balloon. The weight loss was similar to that seen in previous studies of endoscopically placed balloons. In addition, Elipse therapy led to improvements in waist circumference, several metabolic parameters, and overall quality of life.
Název v anglickém jazyce
Elipse, the first procedureless gastric balloon for weight loss: a prospective, observational, open-label, multicenter study.
Popis výsledku anglicky
Background and study aims Conventional gastric balloons for weight loss require endoscopy for placement and removal. The Elipse device is swallowed, resides in the stomach for 4 months, and is then expelled. The objectives of this study were to assess the safety of Elipse and to measure its effects on weight loss, metabolic parameters, and quality of life. Methods Each participant swallowed one Elipse device, which was filled with 550mL of filling fluid through a thin delivery catheter that was then removed. Weight was measured every 2 weeks, and metabolic parameters and quality of life were assessed at baseline and at trial exit. Results 34 patients, with a mean body mass index of 34.8 kg/m(2), were enrolled. All 34 patients successfully swallowed the Elipse device. All adverse events were either self-limiting or resolved with medication. All balloons were safely excreted. At 4 months, the mean percent total body weight loss was 10%. Mean waist circumference was reduced by 8.4cm. Improvements were also seen in hemoglobin A1c, triglycerides, low density lipoprotein, and blood pressure. At trial exit, quality of life measures had improved across all domains. Conclusion These results demonstrate clinically significant weight loss with the Elipse, the first procedureless gastric balloon. The weight loss was similar to that seen in previous studies of endoscopically placed balloons. In addition, Elipse therapy led to improvements in waist circumference, several metabolic parameters, and overall quality of life.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30219 - Gastroenterology and hepatology
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ENDOSCOPY
ISSN
0013-726X
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
154-160
Kód UT WoS článku
000394257500010
EID výsledku v databázi Scopus
2-s2.0-85004190313