Analysis and Modeling of Secondary X-ray Effect on Structure of Skiagraphy Images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F18%3AA2001UFB" target="_blank" >RIV/61988987:17110/18:A2001UFB - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis and Modeling of Secondary X-ray Effect on Structure of Skiagraphy Images
Popis výsledku v původním jazyce
Secondary X-ray effect is a significant phenomenon which is linked with the X-ray imaging. Besides an impact on the human organism, it may significantly influence recording devices such as the skiagraphy images. During the RTG irradiation, the secondary X-ray is being distributed to its surrounding, and may affect skiagraphy images which are stored in the clinical workplace. The secondary irradiation causes a partially irreversible deterioration resulting to a worse quality of the clinical information. More times is particular image affected by the secondary X-ray, we obtain a worse quality and reproducibility of the clinical information. Unfortunately, there is not clinically objective approach for determining the X-ray effect level before using particular skiagraphy image. We have done analysis and modelling of the secondary X-ray effect on skiagraphy records within several experiments. A level of the X-ray irradiation is being modelled via the multiregional segmentation method allowing for extraction image areas affected by irradiation. Consequently, this model allows for a calculation of image features representing the irradiation level, and estimates a quantification of the secondary X-ray irradiation.
Název v anglickém jazyce
Analysis and Modeling of Secondary X-ray Effect on Structure of Skiagraphy Images
Popis výsledku anglicky
Secondary X-ray effect is a significant phenomenon which is linked with the X-ray imaging. Besides an impact on the human organism, it may significantly influence recording devices such as the skiagraphy images. During the RTG irradiation, the secondary X-ray is being distributed to its surrounding, and may affect skiagraphy images which are stored in the clinical workplace. The secondary irradiation causes a partially irreversible deterioration resulting to a worse quality of the clinical information. More times is particular image affected by the secondary X-ray, we obtain a worse quality and reproducibility of the clinical information. Unfortunately, there is not clinically objective approach for determining the X-ray effect level before using particular skiagraphy image. We have done analysis and modelling of the secondary X-ray effect on skiagraphy records within several experiments. A level of the X-ray irradiation is being modelled via the multiregional segmentation method allowing for extraction image areas affected by irradiation. Consequently, this model allows for a calculation of image features representing the irradiation level, and estimates a quantification of the secondary X-ray irradiation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30500 - Other medical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
BIODEVICES 2018 - 11th International Conference on Biomedical Electronics and Devices
ISBN
978-3-030-31634-1
ISSN
1680-0737
e-ISSN
1433-9277
Počet stran výsledku
8
Strana od-do
30-38
Název nakladatele
Springer, Cham
Místo vydání
Springer Nature Switzerland AG 2020
Místo konání akce
Madeira
Datum konání akce
19. 1. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—