Estimated glomerular filtration rate in patients overdosed with gentamicin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F20%3AA21025ZP" target="_blank" >RIV/61988987:17110/20:A21025ZP - isvavai.cz</a>
Výsledek na webu
<a href="https://www.degruyter.com/view/journals/labm/44/1/article-p35.xml" target="_blank" >https://www.degruyter.com/view/journals/labm/44/1/article-p35.xml</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/labmed-2019-0124" target="_blank" >10.1515/labmed-2019-0124</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Estimated glomerular filtration rate in patients overdosed with gentamicin
Popis výsledku v původním jazyce
Background: The aim of this study was to compare the estimated glomerular filtration rate (eGFR) from serum creatinine (eGFRcrea) and cystatin C (eGFRcys) in patients with elevated serum trough levels of gentamicin before the next planned dose during treatment in the intensive care unit (ICU). Methods: This was a retrospective observational study. Patients who stayed in an ICU, received a once-daily dose of gentamicin, and who had results from all serum gentamicin trough levels, eGFRcrea and eGFRcys analyses were included in the study. Overdosed patients were defined as those with serum gentamicin trough levels above 1 mg/L before the next dose. Gentamicin was measured by a particle-enhanced turbidimetric immunoassay (PETIA). Creatinine and cystatin C were measured by standardized methods.
Název v anglickém jazyce
Estimated glomerular filtration rate in patients overdosed with gentamicin
Popis výsledku anglicky
Background: The aim of this study was to compare the estimated glomerular filtration rate (eGFR) from serum creatinine (eGFRcrea) and cystatin C (eGFRcys) in patients with elevated serum trough levels of gentamicin before the next planned dose during treatment in the intensive care unit (ICU). Methods: This was a retrospective observational study. Patients who stayed in an ICU, received a once-daily dose of gentamicin, and who had results from all serum gentamicin trough levels, eGFRcrea and eGFRcys analyses were included in the study. Overdosed patients were defined as those with serum gentamicin trough levels above 1 mg/L before the next dose. Gentamicin was measured by a particle-enhanced turbidimetric immunoassay (PETIA). Creatinine and cystatin C were measured by standardized methods.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF LABORATORY MEDICINE
ISSN
2567-9430
e-ISSN
2567-9449
Svazek periodika
44
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
4
Strana od-do
35-39
Kód UT WoS článku
000512769200007