Reliability of a measurement technique for Achilles tendon length
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17450%2F19%3AA2002011" target="_blank" >RIV/61988987:17450/19:A2002011 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.tandfonline.com/doi/full/10.1080/02640414.2019.1635375" target="_blank" >https://www.tandfonline.com/doi/full/10.1080/02640414.2019.1635375</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/02640414.2019.1635375" target="_blank" >10.1080/02640414.2019.1635375</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reliability of a measurement technique for Achilles tendon length
Popis výsledku v původním jazyce
Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.
Název v anglickém jazyce
Reliability of a measurement technique for Achilles tendon length
Popis výsledku anglicky
Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Sport Sciences
ISSN
0264-0414
e-ISSN
1466-447X
Svazek periodika
37
Číslo periodika v rámci svazku
20
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
2389-2395
Kód UT WoS článku
000475198800001
EID výsledku v databázi Scopus
2-s2.0-85068103344