The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F12%3A86083723" target="_blank" >RIV/61989100:27120/12:86083723 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test.
Popis výsledku v původním jazyce
The value of air permeability or the value of n50 provides important information about the impermeability of the building envelope and thus the quality of internal environment of the building. It is also one of the main evaluation criteria in classifyingenergy efficient buildings. Air permeability is determined by Blower Door Test where the fan blows air in or out from the measured area. The measurement is performed in a overpressure and afterwards in a underpressure during which the leaks are detected. The frame is usually placed into the front door which themselves is a link part in the building envelope and thus the rate of leakage completely denies. The effect of leakage of the front door is so significant that it can often cause a misclassification of the energy efficient buildings. We have tested this hypothesis by Blower Door Test on a passive timber construction build in 2007.
Název v anglickém jazyce
The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test.
Popis výsledku anglicky
The value of air permeability or the value of n50 provides important information about the impermeability of the building envelope and thus the quality of internal environment of the building. It is also one of the main evaluation criteria in classifyingenergy efficient buildings. Air permeability is determined by Blower Door Test where the fan blows air in or out from the measured area. The measurement is performed in a overpressure and afterwards in a underpressure during which the leaks are detected. The frame is usually placed into the front door which themselves is a link part in the building envelope and thus the rate of leakage completely denies. The effect of leakage of the front door is so significant that it can often cause a misclassification of the energy efficient buildings. We have tested this hypothesis by Blower Door Test on a passive timber construction build in 2007.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.20.0013" target="_blank" >EE2.3.20.0013: Tvorba a internacionalizace špičkových vědeckých týmů a zvyšování jejich excelence na Fakultě stavební VŠB-TUO</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Buildings and Environment 2012 : digital proceedings : October 25th-26th 2012, Faculty of Civil Engineering, Brno University of Technology
ISBN
978-80-214-4505-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
159-162
Název nakladatele
Vysoké učení technické v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
25. 10. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—