Investigation of selected physical parameters of cementitious composite during sequential fracture test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F14%3A86091747" target="_blank" >RIV/61989100:27120/14:86091747 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.scientific.net/AMR.969.228" target="_blank" >http://www.scientific.net/AMR.969.228</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.969.228" target="_blank" >10.4028/www.scientific.net/AMR.969.228</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigation of selected physical parameters of cementitious composite during sequential fracture test
Popis výsledku v původním jazyce
The paper is focusing on the investigation of the effective crack length obtained from bending test on concrete notched beams with the complementary measurements of ultrasound passing time through the tested concrete specimen. The ultrasound passing timemeasurements are performed on several stages of the fracture process along the specimen ligament for each tested notched beam. Gained results of the time of ultrasound pulse needed to pass through specimens' failure zone, i.e. its dependence on the crack length or opening, provide information which may help to identify the process of crack formation without the visible indications. The fracture tests are conducted for a set of specimens differing in the notch length. Changes of the ultrasound passing times with increasing effective crack length are observed and discussed.
Název v anglickém jazyce
Investigation of selected physical parameters of cementitious composite during sequential fracture test
Popis výsledku anglicky
The paper is focusing on the investigation of the effective crack length obtained from bending test on concrete notched beams with the complementary measurements of ultrasound passing time through the tested concrete specimen. The ultrasound passing timemeasurements are performed on several stages of the fracture process along the specimen ligament for each tested notched beam. Gained results of the time of ultrasound pulse needed to pass through specimens' failure zone, i.e. its dependence on the crack length or opening, provide information which may help to identify the process of crack formation without the visible indications. The fracture tests are conducted for a set of specimens differing in the notch length. Changes of the ultrasound passing times with increasing effective crack length are observed and discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced Materials Research. Volume 969
ISBN
978-3-03835-147-4
ISSN
1022-6680
e-ISSN
—
Počet stran výsledku
6
Strana od-do
228-233
Název nakladatele
Trans Tech Publications
Místo vydání
Uetikon-Zuerich
Místo konání akce
Vysoké Tatry
Datum konání akce
27. 11. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—