Movement of CO2 in the room
Popis výsledku v původním jazyce
CO2 concentration in rooms, where we spend most of our lives, has become a problem that is solved by ventilation. In buildings, where is the ventilation additionally implemented, has become a problem with distribution systems. Between professionals is solved system so called "Cascade ventilation", where is enough to incriminated room was at the junction of the inlet and exhaust air. If this assumption will be confirmed, it will facilitate the management of air distribution systems, especially in the case of renovations. Therefore would be no implementation of ceilings, which constitute a considerable part of the budget. Cascade system is based on the principle of Dalton's Law of partial pressures. For test of this theory has been used room, where is located 8 CO2 sensors. Here was monitored the movement of CO2 concentration from resources (human) and its distribution through the room in horizontal and vertical direction. The experiment was also simplified simulated in a computer progra
Název v anglickém jazyce
Movement of CO2 in the room
Popis výsledku anglicky
CO2 concentration in rooms, where we spend most of our lives, has become a problem that is solved by ventilation. In buildings, where is the ventilation additionally implemented, has become a problem with distribution systems. Between professionals is solved system so called "Cascade ventilation", where is enough to incriminated room was at the junction of the inlet and exhaust air. If this assumption will be confirmed, it will facilitate the management of air distribution systems, especially in the case of renovations. Therefore would be no implementation of ceilings, which constitute a considerable part of the budget. Cascade system is based on the principle of Dalton's Law of partial pressures. For test of this theory has been used room, where is located 8 CO2 sensors. Here was monitored the movement of CO2 concentration from resources (human) and its distribution through the room in horizontal and vertical direction. The experiment was also simplified simulated in a computer progra
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
enviBUILD 2015 : International Conference Buildings and Environment 2015 : 15th - 16th October 2015, University Library, Ventúrska 11, Bratislava, Slovakia
ISBN
978-80-227-4469-0
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Slovenská technická univerzita
Místo vydání
Bratislava
Místo konání akce
Bratislava
Datum konání akce
15. 10. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—