Analysis of foundation slab focused on strain gauge measurment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F17%3A10237636" target="_blank" >RIV/61989100:27120/17:10237636 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.738.175" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.738.175</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.738.175" target="_blank" >10.4028/www.scientific.net/KEM.738.175</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of foundation slab focused on strain gauge measurment
Popis výsledku v původním jazyce
nteraction analysis between foundation structure and subsoil and credential assessment of stress in the subsoil and internal forces in foundation structure are discussed in research conferences and scientific journals in the long term. Since 2012 research team at Faculty of civil engineering VSB-TU Ostrava has tested a few slabs with dimensions 2 x 2 m with thickness from 0.12 to 0.2 m. Complex testing comprises measurement of slab deformations, stress in the subsoil and measurement of stress in foundation slab using strain gauges. Slabs were made of plain concrete, reinforced concrete, pre-stressed concrete and fibre concrete. In the paper there are particular test results of stress measured in the foundation structure. Measured values are compared with calculated values. Strain gauge measurement efficiency and optimisation is discussed.
Název v anglickém jazyce
Analysis of foundation slab focused on strain gauge measurment
Popis výsledku anglicky
nteraction analysis between foundation structure and subsoil and credential assessment of stress in the subsoil and internal forces in foundation structure are discussed in research conferences and scientific journals in the long term. Since 2012 research team at Faculty of civil engineering VSB-TU Ostrava has tested a few slabs with dimensions 2 x 2 m with thickness from 0.12 to 0.2 m. Complex testing comprises measurement of slab deformations, stress in the subsoil and measurement of stress in foundation slab using strain gauges. Slabs were made of plain concrete, reinforced concrete, pre-stressed concrete and fibre concrete. In the paper there are particular test results of stress measured in the foundation structure. Measured values are compared with calculated values. Strain gauge measurement efficiency and optimisation is discussed.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Key engineering materials. Volume 738
ISBN
978-3-0357-1114-1
Počet stran výsledku
10
Strana od-do
175-184
Počet stran knihy
342
Název nakladatele
Trans Tech Publication Ltd
Místo vydání
Durnten-Zurich
Kód UT WoS kapitoly
—