Infrared thermographic measurement of the surface temperature and emissivity of glossy materials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F18%3A10238019" target="_blank" >RIV/61989100:27120/18:10238019 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27240/18:10238019 RIV/61989100:27350/18:10238019
Výsledek na webu
<a href="http://journals.sagepub.com/doi/abs/10.1177/1744259117731344" target="_blank" >http://journals.sagepub.com/doi/abs/10.1177/1744259117731344</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/1744259117731344" target="_blank" >10.1177/1744259117731344</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Infrared thermographic measurement of the surface temperature and emissivity of glossy materials
Popis výsledku v původním jazyce
Determination of the surface temperature and emissivity of glossy materials is a complicated task due to the relatively wide range of emissivity values and the reflection of infrared radiation from surrounding objects. As a consequence, standard methods used in infrared thermography are not applicable. In this article, an alternative method is proposed for the measurement of the surface temperature and emissivity of glossy materials used in the external structures of buildings that is based on an external source of thermal radiation. It is shown that the method gives quite accurate values of emissivity of both low- and high-emissivity glossy materials, whereas the surface temperature of low-emissivity glossy materials is less accurate and strongly depends on the accuracy of the used thermal camera.
Název v anglickém jazyce
Infrared thermographic measurement of the surface temperature and emissivity of glossy materials
Popis výsledku anglicky
Determination of the surface temperature and emissivity of glossy materials is a complicated task due to the relatively wide range of emissivity values and the reflection of infrared radiation from surrounding objects. As a consequence, standard methods used in infrared thermography are not applicable. In this article, an alternative method is proposed for the measurement of the surface temperature and emissivity of glossy materials used in the external structures of buildings that is based on an external source of thermal radiation. It is shown that the method gives quite accurate values of emissivity of both low- and high-emissivity glossy materials, whereas the surface temperature of low-emissivity glossy materials is less accurate and strongly depends on the accuracy of the used thermal camera.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1406" target="_blank" >LO1406: Institut čistých technologií těžby a užití energetických surovin - Projekt udržitelnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Building Physics
ISSN
1744-2591
e-ISSN
—
Svazek periodika
41
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
533-546