Measurement of Volume Changes of Cement Concrete in Large- Dimensional Samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F18%3A10238297" target="_blank" >RIV/61989100:27120/18:10238297 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.272.102" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/SSP.272.102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.272.102" target="_blank" >10.4028/www.scientific.net/SSP.272.102</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Volume Changes of Cement Concrete in Large- Dimensional Samples
Popis výsledku v původním jazyce
The subject of the paper is research on the development of volume changes (especially shrinkage) on cement concrete. This is a measurement of shrinkage on large samples using string strain gauges both internal and external. Parallel to this measurement, according to the real concreting conditions, the volume changes will be measured by means of shrinkage drains in the test laboratory. This will make it possible to compare a comparatively progressive method of measuring volume changes with the real behavior of the same concrete in the structure. The measurement of volume changes by the shrinkage drains is a comparatively rare test allowing continuous volume changes to be measured from the beginning of the setting of the concrete. It is possible to capture the entire process of hydration of concrete. The paper will describe the technology of measurement and comparison of both methods on ordinary concrete.
Název v anglickém jazyce
Measurement of Volume Changes of Cement Concrete in Large- Dimensional Samples
Popis výsledku anglicky
The subject of the paper is research on the development of volume changes (especially shrinkage) on cement concrete. This is a measurement of shrinkage on large samples using string strain gauges both internal and external. Parallel to this measurement, according to the real concreting conditions, the volume changes will be measured by means of shrinkage drains in the test laboratory. This will make it possible to compare a comparatively progressive method of measuring volume changes with the real behavior of the same concrete in the structure. The measurement of volume changes by the shrinkage drains is a comparatively rare test allowing continuous volume changes to be measured from the beginning of the setting of the concrete. It is possible to capture the entire process of hydration of concrete. The paper will describe the technology of measurement and comparison of both methods on ordinary concrete.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Solid State Phenomena. Volume 272
ISBN
978-3-0357-1284-1
ISSN
1012-0394
e-ISSN
1662-9779
Počet stran výsledku
5
Strana od-do
102-106
Název nakladatele
Trans Tech Publications
Místo vydání
Curych
Místo konání akce
Litomyšl
Datum konání akce
22. 11. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—