Effect of different concrete material parameters on the accuracy of FEM model of diffusion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F19%3A10242631" target="_blank" >RIV/61989100:27120/19:10242631 - isvavai.cz</a>
Výsledek na webu
<a href="https://aip.scitation.org/doi/abs/10.1063/1.5114117" target="_blank" >https://aip.scitation.org/doi/abs/10.1063/1.5114117</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5114117" target="_blank" >10.1063/1.5114117</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of different concrete material parameters on the accuracy of FEM model of diffusion
Popis výsledku v původním jazyce
The article focuses on the optimization of the numerical 2D chloride diffusion model applicable in the analysis of the initiation of corrosion on the reinforcement in the concrete. The article deals with optimizing the mesh of finite elements in terms of their size and also considers the effect of length of the time step the non-linear calculation. It takes into account the change of the diffusion coefficient over the time, i.e. the effect of aging. Results are compared with the 1D and also 2D analytical model. The work includes a study of selected concrete mixtures from classical and high performance concrete. The effect of the diffusion coefficient on the accuracy of the chloride ion concentration results is observed with respect to the topology of the mesh size and time step size. (C) 2019 Author(s).
Název v anglickém jazyce
Effect of different concrete material parameters on the accuracy of FEM model of diffusion
Popis výsledku anglicky
The article focuses on the optimization of the numerical 2D chloride diffusion model applicable in the analysis of the initiation of corrosion on the reinforcement in the concrete. The article deals with optimizing the mesh of finite elements in terms of their size and also considers the effect of length of the time step the non-linear calculation. It takes into account the change of the diffusion coefficient over the time, i.e. the effect of aging. Results are compared with the 1D and also 2D analytical model. The work includes a study of selected concrete mixtures from classical and high performance concrete. The effect of the diffusion coefficient on the accuracy of the chloride ion concentration results is observed with respect to the topology of the mesh size and time step size. (C) 2019 Author(s).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings. Volume 2116
ISBN
978-0-7354-1854-7
ISSN
0094-243X
e-ISSN
1551-7616
Počet stran výsledku
4
Strana od-do
4
Název nakladatele
American Institute of Physics
Místo vydání
Melville
Místo konání akce
Rhodos
Datum konání akce
13. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—