Measurement of acoustic emission at fibre reinforcement concrete slab with subsoil
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F19%3A10242698" target="_blank" >RIV/61989100:27120/19:10242698 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26110/19:PU133063
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/549/1/012013" target="_blank" >http://dx.doi.org/10.1088/1757-899X/549/1/012013</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/549/1/012013" target="_blank" >10.1088/1757-899X/549/1/012013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of acoustic emission at fibre reinforcement concrete slab with subsoil
Popis výsledku v původním jazyce
The paper deals with the possibility of using the acoustic emission (AE) measurement for the identification of cracks and failure in fibre concrete slabs in interaction with subsoil. In this specific task it is not possible to check visually cracking on the slab bottom surface. The research task included an experimental load test of a slab and supplemented laboratory testing to determine the mechanical properties of fibre concrete. The concrete used has a dosage of 25 kg/m3 fibres. Laboratory tests included cube and cylindrical compressive strength, flexural strength and split tensile strength. Homogeneity of the concrete mixture, i.e. uniform distribution of the fibres, was proven with testing of the split tensile strength both evenly and perpendicularly to the direction of filling the concrete mixture into the form. Experimental load test of slab on subsoil was performed on fibre concrete slab with plan dimensions 2000 x 2000 mm and thickness 150 mm. Concrete slab was loaded in the middle with force load step 75 kN. AE measurements were provided using track sensors.
Název v anglickém jazyce
Measurement of acoustic emission at fibre reinforcement concrete slab with subsoil
Popis výsledku anglicky
The paper deals with the possibility of using the acoustic emission (AE) measurement for the identification of cracks and failure in fibre concrete slabs in interaction with subsoil. In this specific task it is not possible to check visually cracking on the slab bottom surface. The research task included an experimental load test of a slab and supplemented laboratory testing to determine the mechanical properties of fibre concrete. The concrete used has a dosage of 25 kg/m3 fibres. Laboratory tests included cube and cylindrical compressive strength, flexural strength and split tensile strength. Homogeneity of the concrete mixture, i.e. uniform distribution of the fibres, was proven with testing of the split tensile strength both evenly and perpendicularly to the direction of filling the concrete mixture into the form. Experimental load test of slab on subsoil was performed on fibre concrete slab with plan dimensions 2000 x 2000 mm and thickness 150 mm. Concrete slab was loaded in the middle with force load step 75 kN. AE measurements were provided using track sensors.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering. Volume 549
ISBN
—
ISSN
1757-8981
e-ISSN
1757-899X
Počet stran výsledku
9
Strana od-do
1-9
Název nakladatele
IOP Publishing
Místo vydání
Bristol
Místo konání akce
Zuberec
Datum konání akce
29. 5. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—