Comparison of Experimental Testing and Numerical Modelling of Double-Shear Bolted Connections with Slotted-In Steel Plates in Squared Timber
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F22%3A10251542" target="_blank" >RIV/61989100:27120/22:10251542 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Experimental Testing and Numerical Modelling of Double-Shear Bolted Connections with Slotted-In Steel Plates in Squared Timber
Popis výsledku v původním jazyce
Proper design of connections is one of the most important areas in timber structures. The commonly used connections are dowel-type connections, which are often used in combination with steel plates slotted into cut-outs in timber members. The presented paper deals with the behavior of double-shear bolted connections of squared timber with slotted-in steel plates. Several variants of connections with different distances between the fastener and the loaded end were selected for the experimental testing. A total of three types of test specimens were made from spruce timber, for which their selected physical properties were determined and evaluated before the experimental testing. Test specimens of bolted connections were first tested in tension parallel to the grain until failure under quasi-static loading. The connections were broken by splitting. Ductile failure preceded brittle failure. The actual load-carrying capacities were lowest for the lowest end distance. The results of some experiments were then compared with a nonlinear numerical analysis based on the finite element method using ANSYS Mechanical APDL.
Název v anglickém jazyce
Comparison of Experimental Testing and Numerical Modelling of Double-Shear Bolted Connections with Slotted-In Steel Plates in Squared Timber
Popis výsledku anglicky
Proper design of connections is one of the most important areas in timber structures. The commonly used connections are dowel-type connections, which are often used in combination with steel plates slotted into cut-outs in timber members. The presented paper deals with the behavior of double-shear bolted connections of squared timber with slotted-in steel plates. Several variants of connections with different distances between the fastener and the loaded end were selected for the experimental testing. A total of three types of test specimens were made from spruce timber, for which their selected physical properties were determined and evaluated before the experimental testing. Test specimens of bolted connections were first tested in tension parallel to the grain until failure under quasi-static loading. The connections were broken by splitting. Ductile failure preceded brittle failure. The actual load-carrying capacities were lowest for the lowest end distance. The results of some experiments were then compared with a nonlinear numerical analysis based on the finite element method using ANSYS Mechanical APDL.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20100 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Modelování v mechanice 2022 : 20. ročník mezinárodní konference : sborník rozšířených abstraktů : 26.-27.5.2022 = Modelling in Mechanics 2022 : 20th international conference : proceedings of extended abstracts : 26th and 27th May 2022
ISBN
978-80-248-4609-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
"neuvedeno"
Název nakladatele
Vysoká škola báňská - Technická univerzita Ostrava
Místo vydání
Ostrava
Místo konání akce
Ostrava
Datum konání akce
26. 5. 2022
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—