Laboratory equipment for testing of hollow-fibre membrane properties
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27200%2F13%3A86086461" target="_blank" >RIV/61989100:27200/13:86086461 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27640/13:86086461
Výsledek na webu
<a href="http://dx.doi.org/10.2495/WS130111" target="_blank" >http://dx.doi.org/10.2495/WS130111</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2495/WS130111" target="_blank" >10.2495/WS130111</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laboratory equipment for testing of hollow-fibre membrane properties
Popis výsledku v původním jazyce
Water has major role at present. Its usage is determined by its quality, which is supported by regulations in many countries. In real life, technology using membrane elements is widely used for water purification. Commonly, membrane modules in the form of hollow fibres are applied. There are modules made from different porous and polymeric materials on the market. Laboratory equipment was constructed to compare different commercially available membranes in this study. The equipment was designed for thetesting of hollow-fibre membranes and for observing various parameters during the performance of volatile organic compound (toluene) separation. The device allows testing either parameters of individually selected hollow-fibre membranes or parallel measurements of the commercially available module as a whole to compare with an individual fibre. The equipment was used for pilot testing in laboratory conditions. Efficiencies of toluene separation from water under various flow rates by usin
Název v anglickém jazyce
Laboratory equipment for testing of hollow-fibre membrane properties
Popis výsledku anglicky
Water has major role at present. Its usage is determined by its quality, which is supported by regulations in many countries. In real life, technology using membrane elements is widely used for water purification. Commonly, membrane modules in the form of hollow fibres are applied. There are modules made from different porous and polymeric materials on the market. Laboratory equipment was constructed to compare different commercially available membranes in this study. The equipment was designed for thetesting of hollow-fibre membranes and for observing various parameters during the performance of volatile organic compound (toluene) separation. The device allows testing either parameters of individually selected hollow-fibre membranes or parallel measurements of the commercially available module as a whole to compare with an individual fibre. The equipment was used for pilot testing in laboratory conditions. Efficiencies of toluene separation from water under various flow rates by usin
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010552" target="_blank" >TA01010552: Využití membrán s nano-póry pro snižování zdravotních rizik VOC z malých vodních zdrojů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
WIT Transactions on Ecology and the Environment. Volume 178
ISBN
978-1-84564-742-1
ISSN
1743-3541
e-ISSN
—
Počet stran výsledku
7
Strana od-do
125-131
Název nakladatele
WIT Press
Místo vydání
Southampton
Místo konání akce
New Forest
Datum konání akce
4. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—