Effects Of Compressed Air Foam Application On Heat Conditions In Fire Within A Closed Space
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27200%2F15%3A86095174" target="_blank" >RIV/61989100:27200/15:86095174 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.degruyter.com/view/j/tvsbses.2015.10.issue-2/tvsbses-2015-0009/tvsbses-2015-0009.xml?format=INT" target="_blank" >http://www.degruyter.com/view/j/tvsbses.2015.10.issue-2/tvsbses-2015-0009/tvsbses-2015-0009.xml?format=INT</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/tvsbses-2015-0009" target="_blank" >10.1515/tvsbses-2015-0009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects Of Compressed Air Foam Application On Heat Conditions In Fire Within A Closed Space
Popis výsledku v původním jazyce
This article evaluates the knowledge obtained in firefighting tests using compressed air foam system (CAFS) within a confined space. Six experiments were conducted for verification during the cooling of rooms and the self-extinguishing effect. The simulation was for a fully developed fire within a room. The fuel was chosen to simulate ordinary combustible materials utilized in residential areas. Mantel thermocouples were placed in the rooms to record the temperature changes. Compressed air foam was first applied with a standard fire hose nozzle to the ceiling and then to the epicenter of fire. Fire extinguishing was initiated after reaching the desired temperature in the room. The temperature for the start of fire extinguishing matched the third phaseof development of a fire. Fire extinguishing was terminated after no obvious signs of fire were shown in epicenter of fire. The outputs of the experiments were evaluated on the basis of the amount of time passed for the temperature to dro
Název v anglickém jazyce
Effects Of Compressed Air Foam Application On Heat Conditions In Fire Within A Closed Space
Popis výsledku anglicky
This article evaluates the knowledge obtained in firefighting tests using compressed air foam system (CAFS) within a confined space. Six experiments were conducted for verification during the cooling of rooms and the self-extinguishing effect. The simulation was for a fully developed fire within a room. The fuel was chosen to simulate ordinary combustible materials utilized in residential areas. Mantel thermocouples were placed in the rooms to record the temperature changes. Compressed air foam was first applied with a standard fire hose nozzle to the ceiling and then to the epicenter of fire. Fire extinguishing was initiated after reaching the desired temperature in the room. The temperature for the start of fire extinguishing matched the third phaseof development of a fire. Fire extinguishing was terminated after no obvious signs of fire were shown in epicenter of fire. The outputs of the experiments were evaluated on the basis of the amount of time passed for the temperature to dro
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AQ - Bezpečnost a ochrana zdraví, člověk – stroj
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sborník vědeckých prací VŠB - TUO, Řada bezpečnostní inženýrství
ISSN
1801-1764
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
20-25
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—