MICROBIAL CONTAMINATION ASSESSMENT OF FIREFIGHTING WATER FOR WATER SUPPLY PURPOSES AND THE POSSIBILITY OF DISINFECTION
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27200%2F24%3A10257618" target="_blank" >RIV/61989100:27200/24:10257618 - isvavai.cz</a>
Výsledek na webu
<a href="https://epslibrary.at/sgem_jresearch_publication_view.php?page=view&editid1=10056" target="_blank" >https://epslibrary.at/sgem_jresearch_publication_view.php?page=view&editid1=10056</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5593/sgem2024v/3.2/s11.10" target="_blank" >10.5593/sgem2024v/3.2/s11.10</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MICROBIAL CONTAMINATION ASSESSMENT OF FIREFIGHTING WATER FOR WATER SUPPLY PURPOSES AND THE POSSIBILITY OF DISINFECTION
Popis výsledku v původním jazyce
This paper deals with the results of research on the laboratory analysis of firefighting water in fire trucks and the possibility of its disinfection for subsequent use as an alternative source of safe water supply to the affected areas. The quality of the water in these vehicles after filling the internal tank is relatively unclear. For this purpose, over a period of 5 months (July to November), water samples were taken from firefighting trucks. The samples were then analyzed in an accredited laboratory. Laboratory analyzes focused mainly on indicators of microbial pollution. The microbial analysis included the determination of coliform bacteria, E. coli, Legionella spp., Pseudomonas aeruginosa, and cultivable microorganisms. 42 water samples were taken from firefighting trucks at 31 fire protection units across the Czech Republic. According to the chosen legislation, none of the water samples fulfil the limits of drinking water. This research also focused on measures to ensure safe water in fire truck tanks. The most effective method, based on laboratory analyses, is the use of chemical disinfection, especially chlorine and chlorine compounds. This method of disinfection is inexpensive and effective for all monitored indicators of microbial contamination.
Název v anglickém jazyce
MICROBIAL CONTAMINATION ASSESSMENT OF FIREFIGHTING WATER FOR WATER SUPPLY PURPOSES AND THE POSSIBILITY OF DISINFECTION
Popis výsledku anglicky
This paper deals with the results of research on the laboratory analysis of firefighting water in fire trucks and the possibility of its disinfection for subsequent use as an alternative source of safe water supply to the affected areas. The quality of the water in these vehicles after filling the internal tank is relatively unclear. For this purpose, over a period of 5 months (July to November), water samples were taken from firefighting trucks. The samples were then analyzed in an accredited laboratory. Laboratory analyzes focused mainly on indicators of microbial pollution. The microbial analysis included the determination of coliform bacteria, E. coli, Legionella spp., Pseudomonas aeruginosa, and cultivable microorganisms. 42 water samples were taken from firefighting trucks at 31 fire protection units across the Czech Republic. According to the chosen legislation, none of the water samples fulfil the limits of drinking water. This research also focused on measures to ensure safe water in fire truck tanks. The most effective method, based on laboratory analyses, is the use of chemical disinfection, especially chlorine and chlorine compounds. This method of disinfection is inexpensive and effective for all monitored indicators of microbial contamination.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10606 - Microbiology
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Multidisciplinary Scientific GeoConference Surveying Geology and Mining Ecology Management, SGEM. Volume 24, Issue 3.2
ISBN
978-619-7603-76-7
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
8
Strana od-do
"77 "- 84
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Vídeň
Datum konání akce
27. 11. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—