Fire Spread Through External Walls of Wooden Materials in Multi-Story Buildings—Part I
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27200%2F25%3A10260077" target="_blank" >RIV/61989100:27200/25:10260077 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2571-6255/8/10/399" target="_blank" >https://www.mdpi.com/2571-6255/8/10/399</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/fire8100399" target="_blank" >10.3390/fire8100399</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fire Spread Through External Walls of Wooden Materials in Multi-Story Buildings—Part I
Popis výsledku v původním jazyce
The increasing use of wooden cladding in multi-storey buildings raises critical fire safety concerns, especially in ventilated façade systems where the chimney effect can accelerate vertical flame spread. This study combines theoretical analysis with three full-scale fire tests to investigate key factors influencing fire propagation, including the influence of façade design details. Results show that poorly constructed lintels and jambs significantly accelerate flame entry into ventilated cavities, while wooden fire barriers—despite being combustible—can delay flame spread if properly installed. These findings inform design recommendations and underscore the need for more robust fire safety strategies in modern timber construction.
Název v anglickém jazyce
Fire Spread Through External Walls of Wooden Materials in Multi-Story Buildings—Part I
Popis výsledku anglicky
The increasing use of wooden cladding in multi-storey buildings raises critical fire safety concerns, especially in ventilated façade systems where the chimney effect can accelerate vertical flame spread. This study combines theoretical analysis with three full-scale fire tests to investigate key factors influencing fire propagation, including the influence of façade design details. Results show that poorly constructed lintels and jambs significantly accelerate flame entry into ventilated cavities, while wooden fire barriers—despite being combustible—can delay flame spread if properly installed. These findings inform design recommendations and underscore the need for more robust fire safety strategies in modern timber construction.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fire
ISSN
2571-6255
e-ISSN
2571-6255
Svazek periodika
8
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
24
Strana od-do
"article number (399)"
Kód UT WoS článku
001602092600001
EID výsledku v databázi Scopus
2-s2.0-105019930822