Měření teploty v průběhu tahové zkoušky oceli 12013 ve střídavém magnetickém poli
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F06%3A00013851" target="_blank" >RIV/61989100:27230/06:00013851 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Temperature Measurement during the Tensile Test of 12013 Steel with Alternating Magnetic Field Application
Popis výsledku v původním jazyce
This paper describes manner and equipment for the temperature measurement during tensile test. The temperature changes were measured with thermocouples. Experimental data has been collected to PC during experiments (in real time). For high-speed temperature measuring, was chosen the thermocouples with a quick time response. For the temperature measuring have been used a measuring set, which consists of personal computer with Windows 98 operating system, data acquisition card ICP-DAS 1800H, daughter board ICP-DAS DB 8225/2 and thermocouples type K with extension grade. During the tensile test with alternating magnetic field application the temperature measuring data were with noise. The data noises were caused with the alternating magnetic field that iswhy there data were filtered. The situation has been described.
Název v anglickém jazyce
Temperature Measurement during the Tensile Test of 12013 Steel with Alternating Magnetic Field Application
Popis výsledku anglicky
This paper describes manner and equipment for the temperature measurement during tensile test. The temperature changes were measured with thermocouples. Experimental data has been collected to PC during experiments (in real time). For high-speed temperature measuring, was chosen the thermocouples with a quick time response. For the temperature measuring have been used a measuring set, which consists of personal computer with Windows 98 operating system, data acquisition card ICP-DAS 1800H, daughter board ICP-DAS DB 8225/2 and thermocouples type K with extension grade. During the tensile test with alternating magnetic field application the temperature measuring data were with noise. The data noises were caused with the alternating magnetic field that iswhy there data were filtered. The situation has been described.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP101%2F04%2FP104" target="_blank" >GP101/04/P104: Determinace vlivu magnetického pole na tvařitelnost feritických ocelí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
65-67
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—