Effect of non-stationary combustion phases on emission factors of selected pollutants and PCDD/F from domestic combustion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F10%3A10224704" target="_blank" >RIV/61989100:27230/10:10224704 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27650/10:10224704 RIV/67985858:_____/10:00359423
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of non-stationary combustion phases on emission factors of selected pollutants and PCDD/F from domestic combustion
Popis výsledku v původním jazyce
It can be concluded that all observed non-stationary states (inappropriate stoking of fuel, wet fuel and boiler operating on lower output than nominal) have deteriorative effects on quality of combustion. Therefore, EFs of almost all selected pollutantsincreased during these states. Moreover, it was observed that only operating of boiler on lower output than nominal caused significant increase of EFs of chlorinated products of incomplete combustion like PCDD/F. Effect of boiler output was observed on modern boiler with semi-continuous automatic stoking, for boilers with manual batch stoking this negative effect would be even more significant. Therefore, connection of boiler with accumulation tank will results in substantial decrease of pollutants emissions because boiler can be operated with nominal output.
Název v anglickém jazyce
Effect of non-stationary combustion phases on emission factors of selected pollutants and PCDD/F from domestic combustion
Popis výsledku anglicky
It can be concluded that all observed non-stationary states (inappropriate stoking of fuel, wet fuel and boiler operating on lower output than nominal) have deteriorative effects on quality of combustion. Therefore, EFs of almost all selected pollutantsincreased during these states. Moreover, it was observed that only operating of boiler on lower output than nominal caused significant increase of EFs of chlorinated products of incomplete combustion like PCDD/F. Effect of boiler output was observed on modern boiler with semi-continuous automatic stoking, for boilers with manual batch stoking this negative effect would be even more significant. Therefore, connection of boiler with accumulation tank will results in substantial decrease of pollutants emissions because boiler can be operated with nominal output.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sborník vědeckých prací VŠB-TU Ostrava, řada strojní
ISSN
1210-0471
e-ISSN
—
Svazek periodika
2010
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
—