Defect detection in pipelines during operation using magnetic flux leakage and phased array ultrasonic method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F14%3A10237906" target="_blank" >RIV/61989100:27230/14:10237906 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com" target="_blank" >https://www.scopus.com</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Defect detection in pipelines during operation using magnetic flux leakage and phased array ultrasonic method
Popis výsledku v původním jazyce
The present article is focused on the non-destructive testing (NDT) inspection of pipelines during operation namely Magnetic Flux Leakage (MFL) method and Phased Array ultrasonic (PA) method. MFL inspection technique is electromagnetic test method primarily used to detect flaws or defects in high-permeability of ferromagnetic metals such as carbon steel tubing, plate, wire rope and tubular parts. PA ultrasonic method is an advanced NDT method that is used to detect component failures i.e. cracks or flaws and thereby determine component quality. Due to the possibility to control parameters such as beam angle and focal distance, this method is very efficient regarding to the defect detection and speed of testing. In this article real pipeline defect was identified by MFL method in the internal pipe inspection. This defect was fully mapped by Phased Array ultrasonic method in the terrain. 3D model of defect in the tested material was created from measured data and obtained by PA method. The real dimensions of the defect determined from measurements by the method of MFL and PA are compared. © 2014. Published by Manufacturing Technology
Název v anglickém jazyce
Defect detection in pipelines during operation using magnetic flux leakage and phased array ultrasonic method
Popis výsledku anglicky
The present article is focused on the non-destructive testing (NDT) inspection of pipelines during operation namely Magnetic Flux Leakage (MFL) method and Phased Array ultrasonic (PA) method. MFL inspection technique is electromagnetic test method primarily used to detect flaws or defects in high-permeability of ferromagnetic metals such as carbon steel tubing, plate, wire rope and tubular parts. PA ultrasonic method is an advanced NDT method that is used to detect component failures i.e. cracks or flaws and thereby determine component quality. Due to the possibility to control parameters such as beam angle and focal distance, this method is very efficient regarding to the defect detection and speed of testing. In this article real pipeline defect was identified by MFL method in the internal pipe inspection. This defect was fully mapped by Phased Array ultrasonic method in the terrain. 3D model of defect in the tested material was created from measured data and obtained by PA method. The real dimensions of the defect determined from measurements by the method of MFL and PA are compared. © 2014. Published by Manufacturing Technology
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
337-341
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84926504195