Popis výsledku v původním jazyce
Pumping station supplies water for irrigation. Maximal capacity 2 x 1.2 m3/s became insu?cient, thus it was upgraded to 2 x 2 m3/s. Paper is focused on design of protection against water hammer in case of sudden pumps trip. Numerical simulation of the most dangerous case (when pumps are giving the maximal ?ow rate) showed that existing air vessels were not able to protect the system and it would be necessary to add new vessels. Special care was paid to in?uence of their connection to the main pipeline,because the resistance of the connection has a signi?cant impact on the scale of pressure pulsations. Finally, the pump trip was performed to verify if the system worked correctly. The test showed that pressure pulsations are lower (better) than computation predicted. This discrepancy was further analysed.
Název v anglickém jazyce
Computation of water hammer protection of modernized pumping station
Popis výsledku anglicky
Pumping station supplies water for irrigation. Maximal capacity 2 x 1.2 m3/s became insu?cient, thus it was upgraded to 2 x 2 m3/s. Paper is focused on design of protection against water hammer in case of sudden pumps trip. Numerical simulation of the most dangerous case (when pumps are giving the maximal ?ow rate) showed that existing air vessels were not able to protect the system and it would be necessary to add new vessels. Special care was paid to in?uence of their connection to the main pipeline,because the resistance of the connection has a signi?cant impact on the scale of pressure pulsations. Finally, the pump trip was performed to verify if the system worked correctly. The test showed that pressure pulsations are lower (better) than computation predicted. This discrepancy was further analysed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0016" target="_blank" >EE2.3.30.0016: Příležitost pro mladé výzkumníky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences. Volume 67
ISBN
978-80-260-5375-0
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
EDP Sciences
Místo vydání
Paříž
Místo konání akce
Kutná Hora
Datum konání akce
19. 11. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000343672100038