Usage of single-chip computers for data collection and control
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F16%3A86097606" target="_blank" >RIV/61989100:27230/16:86097606 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/CarpathianCC.2016.7501081" target="_blank" >http://dx.doi.org/10.1109/CarpathianCC.2016.7501081</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CarpathianCC.2016.7501081" target="_blank" >10.1109/CarpathianCC.2016.7501081</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Usage of single-chip computers for data collection and control
Popis výsledku v původním jazyce
This paper deals with usage of single-chip computers for collection of data and control. The aim is to design a general control system, which is easy to use and easy to implement for other laboratory tasks. Performance of control system is limited by performance of used MCU (PIC 16F873A) and its peripherals (2xPWM, 5xA/D... ). Main task of MCU are communication with upper level and implementation of required control action together with data collection. Communication between control system (IPC) and MCUs is provided by serial interface. In the first step control system defines initialization of MCU (reset needed) for desired laboratory task then continues with the control application. Everything is controlled and monitored from SCADA/HMI system called Control Web. Application is accessible via Internet browser in local network.
Název v anglickém jazyce
Usage of single-chip computers for data collection and control
Popis výsledku anglicky
This paper deals with usage of single-chip computers for collection of data and control. The aim is to design a general control system, which is easy to use and easy to implement for other laboratory tasks. Performance of control system is limited by performance of used MCU (PIC 16F873A) and its peripherals (2xPWM, 5xA/D... ). Main task of MCU are communication with upper level and implementation of required control action together with data collection. Communication between control system (IPC) and MCUs is provided by serial interface. In the first step control system defines initialization of MCU (reset needed) for desired laboratory task then continues with the control application. Everything is controlled and monitored from SCADA/HMI system called Control Web. Application is accessible via Internet browser in local network.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2016 17th International Carpathian Control Conference, ICCC 2016
ISBN
978-1-4673-8606-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
134-139
Název nakladatele
IEEE
Místo vydání
Danvers
Místo konání akce
Tatranská Lomnica
Datum konání akce
29. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—