Full-Range Optical Imaging of Planar Collagen Fiber Orientation Using Polarized Light Microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F21%3A10249898" target="_blank" >RIV/61989100:27230/21:10249898 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/21:00075884 RIV/00216224:14110/21:00119394 RIV/00216305:26210/21:PU142368
Výsledek na webu
<a href="https://www.hindawi.com/journals/bmri/2021/6879765/" target="_blank" >https://www.hindawi.com/journals/bmri/2021/6879765/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2021/6879765" target="_blank" >10.1155/2021/6879765</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Full-Range Optical Imaging of Planar Collagen Fiber Orientation Using Polarized Light Microscopy
Popis výsledku v původním jazyce
A novel method for semiautomated assessment of directions of collagen fibers in soft tissues using histological image analysis is presented. It is based on multiple rotated images obtained via polarized light microscopy without any additional components, i.e., with just two polarizers being either perpendicular or nonperpendicular (rotated). This arrangement breaks the limitation of 90 degrees periodicity of polarized light intensity and evaluates the in-plane fiber orientation over the whole 180 degrees range accurately and quickly. After having verified the method, we used histological specimens of porcine Achilles tendon and aorta to validate the proposed algorithm and to lower the number of rotated images needed for evaluation. Our algorithm is capable to analyze 5.10(5) pixels in one micrograph in a few seconds and is thus a powerful and cheap tool promising a broad application in detection of collagen fiber distribution in soft tissues.
Název v anglickém jazyce
Full-Range Optical Imaging of Planar Collagen Fiber Orientation Using Polarized Light Microscopy
Popis výsledku anglicky
A novel method for semiautomated assessment of directions of collagen fibers in soft tissues using histological image analysis is presented. It is based on multiple rotated images obtained via polarized light microscopy without any additional components, i.e., with just two polarizers being either perpendicular or nonperpendicular (rotated). This arrangement breaks the limitation of 90 degrees periodicity of polarized light intensity and evaluates the in-plane fiber orientation over the whole 180 degrees range accurately and quickly. After having verified the method, we used histological specimens of porcine Achilles tendon and aorta to validate the proposed algorithm and to lower the number of rotated images needed for evaluation. Our algorithm is capable to analyze 5.10(5) pixels in one micrograph in a few seconds and is thus a powerful and cheap tool promising a broad application in detection of collagen fiber distribution in soft tissues.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomed Research International
ISSN
2314-6133
e-ISSN
2314-6141
Svazek periodika
2021
Číslo periodika v rámci svazku
Neuveden
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
nestrankovano
Kód UT WoS článku
000771938700001
EID výsledku v databázi Scopus
—