The Problem of shaft voltage origination in electrical machines was known and studied already at the beginning of the past century. The shaft voltage can occur also by synchronous generator with exciting winding fed from static exciter. When we will notrespect any specific designing and mounting principles it can happen to current flow through bearings. Conductive path is created by closed circuit compounded from motor frame, bearing shields, bearings and shaft. In the other cases it can be concerned acircuit consisted from winding, air gap, bearing, capacitance or possible capacitance of other parts against ground. Different parts of bearings can be damaged by these currents and so it comes to operation state deterioration. In our paper we want to show measuring results of small and large power motors.
Název v anglickém jazyce
Shaft Voltage and Bearing Currents
Popis výsledku anglicky
The Problem of shaft voltage origination in electrical machines was known and studied already at the beginning of the past century. The shaft voltage can occur also by synchronous generator with exciting winding fed from static exciter. When we will notrespect any specific designing and mounting principles it can happen to current flow through bearings. Conductive path is created by closed circuit compounded from motor frame, bearing shields, bearings and shaft. In the other cases it can be concerned acircuit consisted from winding, air gap, bearing, capacitance or possible capacitance of other parts against ground. Different parts of bearings can be damaged by these currents and so it comes to operation state deterioration. In our paper we want to show measuring results of small and large power motors.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník Zeszyty Problemowe z konference Maszyny elektryczne 2002
ISBN
0239-3646
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
37-39
Název nakladatele
Branzowy Osrodek Badawczo Rozwojowy Maszyn Elektrycznych Kom
Místo vydání
Katowice
Místo konání akce
Ustroń - Polsko
Datum konání akce
22. 5. 2002
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—