Deformation of voltage and current waveforms of synchronous machine on pulling out of synchronism
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F04%3A00010303" target="_blank" >RIV/61989100:27240/04:00010303 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Deformation of voltage and current waveforms of synchronous machine on pulling out of synchronism
Popis výsledku v původním jazyce
By the test measurement of effect of pulling out of synchrnism of synchronous machines with salient poles on the electrical power network and synchronous machine was be detect existence of curves deformation of induction voltage. The curves are in all phases deformed with 3.th harmonics of voltage, whose common action forms noncircular vector of voltage betwen null point of electrical power network and null point of synchronous machine winding. If there are these null points connected, is generated thecirculating current surge, that as flowing through the null conductor with frequencies 150 Hz and with amplitude equal to sum of all phases current. Time lag the 3.th harmonic of phase voltage is defined by load angular size. On the pulling out of synchronism is chanced the position ot this 3.th harmonic in face of fundemental harmonic. Per this is possible observe pole instantaneous position.
Název v anglickém jazyce
Deformation of voltage and current waveforms of synchronous machine on pulling out of synchronism
Popis výsledku anglicky
By the test measurement of effect of pulling out of synchrnism of synchronous machines with salient poles on the electrical power network and synchronous machine was be detect existence of curves deformation of induction voltage. The curves are in all phases deformed with 3.th harmonics of voltage, whose common action forms noncircular vector of voltage betwen null point of electrical power network and null point of synchronous machine winding. If there are these null points connected, is generated thecirculating current surge, that as flowing through the null conductor with frequencies 150 Hz and with amplitude equal to sum of all phases current. Time lag the 3.th harmonic of phase voltage is defined by load angular size. On the pulling out of synchronism is chanced the position ot this 3.th harmonic in face of fundemental harmonic. Per this is possible observe pole instantaneous position.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LN00B029" target="_blank" >LN00B029: Materiálově technologické výzkumné centrum</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XII. International Symposium on electric Machinery
ISBN
ISBN 80-01-0306
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
147-153
Název nakladatele
ČVUT FEI Praha
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
8. 9. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—