Rušivé působení flikru v kancelářských prostorách
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F05%3A00012264" target="_blank" >RIV/61989100:27240/05:00012264 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Disturbing Activity of Flicker at the Office
Popis výsledku v původním jazyce
Measuring of fluctuating voltage and fluctuating luminous flux was realized by virtue of request by delegates of Town Lipník. Delegates of Town Lipník decided to realize of measuring in a reaction on repeated reclamation of personnel. Personnel worked atthe new reconstructed offices. The re-construction was realized in August of 2003. Reclamation of personnel started at once after move in of personnel to these offices. Measuring was realized in April of 2004 in morning. At one of office the eclipses ofwindows was realized. The office was equipped by computers; it comes to this, that it is concerned about workstation with displays. The illuminative system was created by fluorescent lamps. The measuring of illumination according to ČSN 360011-3 "The Measuring of Candlelight" was realized at office at the first. According to norm the required illumination was determined 583 lx. The actual illumination on the work-table was measured c. 1000 lx. The measuring of momen-tary values of suppl
Název v anglickém jazyce
Disturbing Activity of Flicker at the Office
Popis výsledku anglicky
Measuring of fluctuating voltage and fluctuating luminous flux was realized by virtue of request by delegates of Town Lipník. Delegates of Town Lipník decided to realize of measuring in a reaction on repeated reclamation of personnel. Personnel worked atthe new reconstructed offices. The re-construction was realized in August of 2003. Reclamation of personnel started at once after move in of personnel to these offices. Measuring was realized in April of 2004 in morning. At one of office the eclipses ofwindows was realized. The office was equipped by computers; it comes to this, that it is concerned about workstation with displays. The illuminative system was created by fluorescent lamps. The measuring of illumination according to ČSN 360011-3 "The Measuring of Candlelight" was realized at office at the first. According to norm the required illumination was determined 583 lx. The actual illumination on the work-table was measured c. 1000 lx. The measuring of momen-tary values of suppl
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F03%2F1162" target="_blank" >GA102/03/1162: Realizace expertního systému pro osvětlování prostorů s vyšší zrakovou náročností</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník Europa LUX
ISBN
3-927787-27-2
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
10-11
Název nakladatele
Achen,d
Místo vydání
Achen
Místo konání akce
Berlín
Datum konání akce
1. 5. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—