Long-Term Heart Rate Variability Assessment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F11%3A86084836" target="_blank" >RIV/61989100:27240/11:86084836 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-642-21729-6_134" target="_blank" >http://dx.doi.org/10.1007/978-3-642-21729-6_134</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-642-21729-6_134" target="_blank" >10.1007/978-3-642-21729-6_134</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long-Term Heart Rate Variability Assessment
Popis výsledku v původním jazyce
Heart rate variability is good diagnostics method not only in cardiology investigation. This kind of investigation is made in long term ECG analysis of Holter's type of examination. This work deals about long the processing and evaluation qualitative changes heart rate. Two detection methods for different kind of obstruct signal were designed and implemented in standalone application. The application was designed and realized detection significant parts of one lead ECG record. Evaluation and testing were done on signals from clinical Physionet database records. Results of evaluation are displayed as numerical values of detected R-R peaks and also visualized by several inspectional charts. The real application test was done on record from children hospital clinic. The tests records represents causes complex sudden death near newborns with successfully prediction indication.
Název v anglickém jazyce
Long-Term Heart Rate Variability Assessment
Popis výsledku anglicky
Heart rate variability is good diagnostics method not only in cardiology investigation. This kind of investigation is made in long term ECG analysis of Holter's type of examination. This work deals about long the processing and evaluation qualitative changes heart rate. Two detection methods for different kind of obstruct signal were designed and implemented in standalone application. The application was designed and realized detection significant parts of one lead ECG record. Evaluation and testing were done on signals from clinical Physionet database records. Results of evaluation are displayed as numerical values of detected R-R peaks and also visualized by several inspectional charts. The real application test was done on record from children hospital clinic. The tests records represents causes complex sudden death near newborns with successfully prediction indication.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011)
ISBN
978-3-642-21728-9
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
3
Strana od-do
532-535
Název nakladatele
Springer
Místo vydání
Berlin
Místo konání akce
Kuala Lumpur
Datum konání akce
20. 6. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000308454300134