Advanced Experimental Medical Diagnostic System Design and Realization
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F12%3A86085741" target="_blank" >RIV/61989100:27240/12:86085741 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27240/12:86089174
Výsledek na webu
<a href="http://dx.doi.org/10.5755/j01.eee.117.1.1060" target="_blank" >http://dx.doi.org/10.5755/j01.eee.117.1.1060</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5755/j01.eee.117.1.1060" target="_blank" >10.5755/j01.eee.117.1.1060</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advanced Experimental Medical Diagnostic System Design and Realization
Popis výsledku v původním jazyce
The aim of this work is to design and realize the experimental diagnostic instrument for biological data measurement. In the biomedical engineering daily live work is necessary to measure and analyze wide range of variables coming primary from humans oranimals. There are measured mostly electrical signals from in vivo or in vitro from the subjects. Concerning these requirements we proposed the cheap and quality balanced measuring device for six channels with 2 kHz and 12 bit ADC resolution equipped with USB bus. Concerning our requirements were realized the photoplethysmography and electrocardiography module connected into measuring device to realize practical bio-signal measurements and tests.
Název v anglickém jazyce
Advanced Experimental Medical Diagnostic System Design and Realization
Popis výsledku anglicky
The aim of this work is to design and realize the experimental diagnostic instrument for biological data measurement. In the biomedical engineering daily live work is necessary to measure and analyze wide range of variables coming primary from humans oranimals. There are measured mostly electrical signals from in vivo or in vitro from the subjects. Concerning these requirements we proposed the cheap and quality balanced measuring device for six channels with 2 kHz and 12 bit ADC resolution equipped with USB bus. Concerning our requirements were realized the photoplethysmography and electrocardiography module connected into measuring device to realize practical bio-signal measurements and tests.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Elektronika ir elektrotechnika
ISSN
1392-1215
e-ISSN
—
Svazek periodika
2012
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
LT - Litevská republika
Počet stran výsledku
6