Influence of thermal turbulences on the optical beam of atmospheric optical link
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86086252" target="_blank" >RIV/61989100:27240/13:86086252 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27230/13:86086252
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6613907" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6613907</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TSP.2013.6613907" target="_blank" >10.1109/TSP.2013.6613907</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of thermal turbulences on the optical beam of atmospheric optical link
Popis výsledku v původním jazyce
This article is dealing with properties overview of thermal turbulences influencing optical beam of atmospheric optical link. The team of authors was focused on simulation of thermal turbulences caused by hotplate heater that heated water up to boiling point. Thermal turbulences were fanned by three high-speed ventilators and were kept in the wooden box to achieve stable conditions with the respect to effect on optical beam transmitted by atmospheric optical link. The measurement of the thermal turbulences influence was performed in distance of 3 and 10 meters from the optical head. The wooden box was placed directly in front of the optical head. Moreover the numerical profile of turbulent behavior was designed for air flow in the wooden box thanks toAnsys Fluent software application.
Název v anglickém jazyce
Influence of thermal turbulences on the optical beam of atmospheric optical link
Popis výsledku anglicky
This article is dealing with properties overview of thermal turbulences influencing optical beam of atmospheric optical link. The team of authors was focused on simulation of thermal turbulences caused by hotplate heater that heated water up to boiling point. Thermal turbulences were fanned by three high-speed ventilators and were kept in the wooden box to achieve stable conditions with the respect to effect on optical beam transmitted by atmospheric optical link. The measurement of the thermal turbulences influence was performed in distance of 3 and 10 meters from the optical head. The wooden box was placed directly in front of the optical head. Moreover the numerical profile of turbulent behavior was designed for air flow in the wooden box thanks toAnsys Fluent software application.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
TSP 2013 : 36th International Conference on Telecommunications and Signal Processing : July 2-4, 2013, Rome, Italy
ISBN
978-1-4799-0403-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
138-143
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Řím
Datum konání akce
2. 7. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000333968000029