Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86086508" target="_blank" >RIV/61989100:27240/13:86086508 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
Popis výsledku v původním jazyce
The paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is createdbased in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector has been created because today digital protection was not able to detect the aforementioned faults (e.g. a fault between ground and insulated wire is not a complete ground fault).Therefore, the measured data in the fault-free situation will be compared with the simulated measured faults data in the 22 kV insulated wire type ofSAX-W.
Název v anglickém jazyce
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
Popis výsledku anglicky
The paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is createdbased in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector has been created because today digital protection was not able to detect the aforementioned faults (e.g. a fault between ground and insulated wire is not a complete ground fault).Therefore, the measured data in the fault-free situation will be compared with the simulated measured faults data in the 22 kV insulated wire type ofSAX-W.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Elektroenergetika 2013 : proceedings of the 7th International Scientific Symposium on Electrical Power Engineering : Stará Lesná, High Tatras, September 18-20, 2013
ISBN
978-80-553-1442-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
352-355
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
18. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000333395100087