Phasor Data Concentrator for Testing and Educational Purposes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86088525" target="_blank" >RIV/61989100:27240/13:86088525 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Phasor Data Concentrator for Testing and Educational Purposes
Popis výsledku v původním jazyce
This paper describes realization of Phasor Data Concentrator (PDC) with basic functionality. The aim of this work was to create very illustrative implementation of PDC in graphical programming language LabVIEW. Described solution can be used in real transmission systems or because of graphical code clarity it can solve as a teaching tool to understand a visualize functionality. Phasor Data Concentrator receives data streams from two or more Phasor Measurement Units (PMU), synchronizes data streams and provides output data stream with defined reporting rate. Features of the PMU for the synchrophasor measurements and a description of data communication protocol defines IEEE Std C37.118.2 (Standard for Synchrophasor Data Transfer for Power Systems). The phasor data concentrator is a system that is used to manage process and respond to dynamic changes in phasor data streams.
Název v anglickém jazyce
Phasor Data Concentrator for Testing and Educational Purposes
Popis výsledku anglicky
This paper describes realization of Phasor Data Concentrator (PDC) with basic functionality. The aim of this work was to create very illustrative implementation of PDC in graphical programming language LabVIEW. Described solution can be used in real transmission systems or because of graphical code clarity it can solve as a teaching tool to understand a visualize functionality. Phasor Data Concentrator receives data streams from two or more Phasor Measurement Units (PMU), synchronizes data streams and provides output data stream with defined reporting rate. Features of the PMU for the synchrophasor measurements and a description of data communication protocol defines IEEE Std C37.118.2 (Standard for Synchrophasor Data Transfer for Power Systems). The phasor data concentrator is a system that is used to manage process and respond to dynamic changes in phasor data streams.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LH12183" target="_blank" >LH12183: Smart instrumentation - Vývoj a ověřování pokročilých měřicích systémů pro aplikační oblast přenosu a distribuce elektrické energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013)
ISBN
978-80-553-1442-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
312-315
Název nakladatele
TECHNICAL UNIV KOSICE, FAC ELECTRICAL ENGRG & INFORMATICS
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
18. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000333395100077