Power transmission lines are often used very inefficiently. A possible way to increase their effectiveness is the use of dynamic thermal rating, instead of the more common static rating. Dynamic thermal rating can be calculated from actual conductor loadand ambient weather conditions using methodology described in IEEE Std. 738-2006. Main purpose of the presented study is to perform a sensitivity analysis of individual variables participating in dynamic thermal rating calculations. The effects of selected input variables on conductor current-carrying capacity and temperature are described as functional dependence using 2D plots. Individual parameters are then ranked according to their influence on the conductor thermal state. (C) 2013 IEEE.
Název v anglickém jazyce
Sensitivity analysis of conductor current-temperature calculations
Popis výsledku anglicky
Power transmission lines are often used very inefficiently. A possible way to increase their effectiveness is the use of dynamic thermal rating, instead of the more common static rating. Dynamic thermal rating can be calculated from actual conductor loadand ambient weather conditions using methodology described in IEEE Std. 738-2006. Main purpose of the presented study is to perform a sensitivity analysis of individual variables participating in dynamic thermal rating calculations. The effects of selected input variables on conductor current-carrying capacity and temperature are described as functional dependence using 2D plots. Individual parameters are then ranked according to their influence on the conductor thermal state. (C) 2013 IEEE.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Canadian Conference on Electrical and Computer Engineering 2013
ISBN
978-1-4799-0032-9
ISSN
0840-7789
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Regina
Datum konání akce
5. 5. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—