Impact of Mains Power Quality on Operation Characteristics of Induction Motor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86089724" target="_blank" >RIV/61989100:27240/14:86089724 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/6835898/?reload=true" target="_blank" >http://ieeexplore.ieee.org/document/6835898/?reload=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EEEIC.2014.6835898" target="_blank" >10.1109/EEEIC.2014.6835898</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Impact of Mains Power Quality on Operation Characteristics of Induction Motor
Popis výsledku v původním jazyce
The paper deals with the impact of chosen main power quality indices, such as the voltage distortion, the voltage unbalance and the voltage dip on operation characteristics of an induction motor rated at 4 kW fed from the frequency converter and AC source. In this paper the motor efficiency and motor power factor are analyzed in dependence on the motor load at rated motor frequency and the maximum permitted standard levels of power quality indices. In particular, it is shown that the greatest impact on motor operation characteristics has the voltage dip, and that the motor efficiency decreases approximately linearly with the level of the voltage distortion and the voltage unbalance in the specific range of motor load. To distinguish the energy characteristic differences, we used the standard deviation.
Název v anglickém jazyce
Impact of Mains Power Quality on Operation Characteristics of Induction Motor
Popis výsledku anglicky
The paper deals with the impact of chosen main power quality indices, such as the voltage distortion, the voltage unbalance and the voltage dip on operation characteristics of an induction motor rated at 4 kW fed from the frequency converter and AC source. In this paper the motor efficiency and motor power factor are analyzed in dependence on the motor load at rated motor frequency and the maximum permitted standard levels of power quality indices. In particular, it is shown that the greatest impact on motor operation characteristics has the voltage dip, and that the motor efficiency decreases approximately linearly with the level of the voltage distortion and the voltage unbalance in the specific range of motor load. To distinguish the energy characteristic differences, we used the standard deviation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2014 14TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC)
ISBN
978-1-4799-4660-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
382-385
Název nakladatele
IEEE
Místo vydání
Vienna
Místo konání akce
Krakow
Datum konání akce
10. 5. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000343491900073