A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86092118" target="_blank" >RIV/61989100:27240/14:86092118 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/CCECE.2014.6900984" target="_blank" >http://dx.doi.org/10.1109/CCECE.2014.6900984</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CCECE.2014.6900984" target="_blank" >10.1109/CCECE.2014.6900984</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement
Popis výsledku v původním jazyce
We proposed a hybrid device, which is capable of measuring either bioelectrical impedance spectroscopy (BIS) or electrical impedance tomography (EIT) based on the Magnitude Ratio and Phase Difference Detection method. Frequency range available for measuring is from 1 kHz to 1 MHz. The device is based on The Freescale Tower system module with S08MM Freescale microcontroller. The proposed device is divided into two modules. One of them includes measurement chain, the second one contains four multiplexers,which connect always four electrodes to the circuit from total amount of sixteen electrodes. Both modules are connected via Tower elevator modules. While measuring impedance the systematic error occured, so we used the Quadratic Interpolation Self-calibration algorithm for calculation of the measured impedance. Calibration was applied on the absolute value of impedance. Calibration on the phase shift has not been done yet, since both input signals to GPD are highly disturbed with the no
Název v anglickém jazyce
A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement
Popis výsledku anglicky
We proposed a hybrid device, which is capable of measuring either bioelectrical impedance spectroscopy (BIS) or electrical impedance tomography (EIT) based on the Magnitude Ratio and Phase Difference Detection method. Frequency range available for measuring is from 1 kHz to 1 MHz. The device is based on The Freescale Tower system module with S08MM Freescale microcontroller. The proposed device is divided into two modules. One of them includes measurement chain, the second one contains four multiplexers,which connect always four electrodes to the circuit from total amount of sixteen electrodes. Both modules are connected via Tower elevator modules. While measuring impedance the systematic error occured, so we used the Quadratic Interpolation Self-calibration algorithm for calculation of the measured impedance. Calibration was applied on the absolute value of impedance. Calibration on the phase shift has not been done yet, since both input signals to GPD are highly disturbed with the no
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Canadian Conference on Electrical and Computer Engineering 2014
ISBN
978-1-4799-3099-9
ISSN
0840-7789
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE
Místo vydání
Vienna
Místo konání akce
Toronto
Datum konání akce
4. 5. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000361017900074