This paper will be dealing with the issues encountered during connection of small power plants to the distribution grid and control of their reactive power. The small power plants considered will comprise cogeneration units fitted with combustion engines. The data obtained for assessment purposes was generated by the biogas station with the installed power per cogeneration unit equals 549 kW and 637 kW respectively. The power plant is linked to the outside MV power line rated for 22 kV. This paper shows the values measured with reference to problems associated with reactive power control. The problems with reactive power occur with multiple sources of reactive power in immediate vicinity (separated by low impedance only). This issue is most often seen when connecting a cogeneration unit to the distribution grid with the compensation system already integrated. Cogeneration units are provided with their own reactive power control, a larger source would have a synchronous generator: That is the source of reactive power, when its performance is increased by excitation. Great problems occurs once this source is connected to the grid with the initial compensation system installed. Each of these sources has its own reactive power control with various sensitivity settings. Their operations reveals conflicts between individual compensating sources. This problem is encountered at majority of small power plants installed in this way.
Název v anglickém jazyce
Reactive Power Control in Cogeneration Units
Popis výsledku anglicky
This paper will be dealing with the issues encountered during connection of small power plants to the distribution grid and control of their reactive power. The small power plants considered will comprise cogeneration units fitted with combustion engines. The data obtained for assessment purposes was generated by the biogas station with the installed power per cogeneration unit equals 549 kW and 637 kW respectively. The power plant is linked to the outside MV power line rated for 22 kV. This paper shows the values measured with reference to problems associated with reactive power control. The problems with reactive power occur with multiple sources of reactive power in immediate vicinity (separated by low impedance only). This issue is most often seen when connecting a cogeneration unit to the distribution grid with the compensation system already integrated. Cogeneration units are provided with their own reactive power control, a larger source would have a synchronous generator: That is the source of reactive power, when its performance is increased by excitation. Great problems occurs once this source is connected to the grid with the initial compensation system installed. Each of these sources has its own reactive power control with various sensitivity settings. Their operations reveals conflicts between individual compensating sources. This problem is encountered at majority of small power plants installed in this way.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings Of The 8th International Scientific Symposium On Electrical Power Engineering (Elektroenergetika 2015)
ISBN
978-80-553-2187-5
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
508-511
Název nakladatele
TECHNICAL UNIV KOSICE, FAC ELECTRICAL ENGRG &amp; INFORMATICS
Místo vydání
Košice
Místo konání akce
Stara Lesna
Datum konání akce
16. 9. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000361561700125