Distance Measuring by Ultrasonic Sensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A86098264" target="_blank" >RIV/61989100:27240/16:86098264 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S2405896316326623" target="_blank" >http://www.sciencedirect.com/science/article/pii/S2405896316326623</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ifacol.2016.12.026" target="_blank" >10.1016/j.ifacol.2016.12.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Distance Measuring by Ultrasonic Sensor
Popis výsledku v původním jazyce
This presentation deals with the verification of the accuracy of measurement distance ultrasonic sensor in the current environment. As a measuring sensor was chosen SFR08 type equipped by an I2C communication interface which allows addressing. This fact makes it simple to create the sensor array. Control and also visualization system was PC based. As communication card was used NI USB 8451. The goal of verification measurements was to determine the actual sensor accuracy especially when measuring longer distances. When evaluating the accuracy of the sensor was not included in temperature compensation of the measured data. (C) 2016
Název v anglickém jazyce
Distance Measuring by Ultrasonic Sensor
Popis výsledku anglicky
This presentation deals with the verification of the accuracy of measurement distance ultrasonic sensor in the current environment. As a measuring sensor was chosen SFR08 type equipped by an I2C communication interface which allows addressing. This fact makes it simple to create the sensor array. Control and also visualization system was PC based. As communication card was used NI USB 8451. The goal of verification measurements was to determine the actual sensor accuracy especially when measuring longer distances. When evaluating the accuracy of the sensor was not included in temperature compensation of the measured data. (C) 2016
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IFAC-PapersOnLine. Volume 48, Issue 4
ISSN
2405-8963
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
25
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
153-158
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85006993819